background image

 

           ACM5000-GV Quick Start (520029-Rev 1.7) 

Page 2

 

 

Enter

 https://192.168.0.1

 into the address bar 

Note:

 

The LAN connected computer must have an IP address in the same network range 

(192.168.0.xxx)  as the 

ACM5004-GV

. If this is not convenient, you can  use the 

ARP Ping command to set the IP address. Refer to the User Manual or online FAQ 

for  details.  The 

ACM5004-GV

  also  has  DHCP  enabled  by  default,  so  it  will 

automatically  accept  any  network  IP  address  assigned  by  any  DHCP  server  on 

your network. It will then respond at both 192.168.0.1 and its DHCP address.

 

 

Log in using the default system user name, 

root,

 

and the password, 

default. 

Welcome

 screen listing the basic configuration steps is displayed  

It is recommended that you set up a  new Administrator  user (in the 

admin

 group with 

full access privileges) and login as this new user for all ongoing administration functions 
(rather than continuing as root). 

 

Select 

System: Administration

. Enter and confirm a new 

System Password

 

and click 

Apply 

  

 

To assign your ACM5004-GV a static IP address or to permanently enable DHCP 
on the primary Ethernet network, select 

System: IP 

then 

Network Interface

 

and  check 

DHCP 

or 

Static 

for 

Configuration  Method

.  Leave  the

  Failover 

Interface 

set to

 None

 

 To configure the ACM5004-GV 

console server 

features:

  

 

Configure the serial port settings and enable  the desired  protocols  and logging 
levels via 

Serial & Network: Serial Port

.  

 

You may also  enable  SSH tunneled  access through the  ACM5004-GV to locally 
networked devices (

hosts

) using 

Serial & Network: Network Hosts

 

 

Configure user access to serial ports via 

Serial & Network: Users & Groups

  

Step 4   Connect the cellular modem

 

 

Select the 

Internal Cellular Modem

 tab on the 

System: Dial

 menu

  

 

The ACM5004-GV supports both  OTASP (

Over-the-Air Service Provisioning

 where 

modem specific parameters can be retrieved via a call to a special phone number) 
and  a  manual  process  where  the  phone  number  and  other  parameters  can  be 
entered manually. 

 

o

 

For OTASP, enter *22899 as the number to be dialed (for Verizon)  

o

 

For  manual  activation  enter  the

  MSL

,

  MDN

  and

  MSID

  values.  Verizon 

have  been  known  to  use  an

  MSL 

o

f  000000 

and  the  phone  number 

assigned to the ACM5004-GV as both the

 MDN 

and

 MSID 

 

Отзывы: