2. INSTALLATION / CONFIGURATION
The Pro-Pack dome camera must be installed by qualified service personnel in accordance with all local and federaI
electrical and building codes. The system should be installed according to Figures 3 through 9.
The device which is connected at end of line, whether it be a dome camera or keyboard controller, must have the
cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is
potentiaI for control signal errors. Total length of the cable for communication should not exceed 3,000 feet.
Figure 5 - Layout of Switches
Termination
on
9 10
9
10
ON
ON
OFF
OFF
Function
Termination
NOT Terminated
D. SETTING UP THE UNIT FOR TERMINATION
Figure 6 - Termination of Dome Camera Data Line