650-

DD

Quick-connector cable  RJ-11 (cotaloge no. 140106 – included)

The following standard lengh cables RJ-11 , can be ordered in length of :

Lengh

Cataloge no.

6m / 20'

140106

10m/33'

140110

15m/50'

140115

20m/67'

140120

Alternative System Configuration

The system enables 4 thermostats and damper to be connected to one power
supply box C-315-4.
 This provides for flexibility and easy of installation in various field conditions.

Safety and Warning Instructions !!!.

Before starting work makesure that the supply cable has been disconnected
from the electrical network.
Installation must be carried out by a certified electrician or licensed technician.
For connection between the thermostat and the power supply box use only
cables with RJ-11 quick-connectors supplied by the manufacturer. It is
forbidden to extend the cables.

Remove the thermostat body fram
from the base 

(1)

.

connect the cable with the RJ-11
to the base 

(2)

.

Use  the connecting screws to
connect the thermostat to
the Gewiss box 

(3)

.

Connect the frame to the thermostat

(4)

.

Installing the Thermostat and
Connecting to the Power Supply Box

2

Operation Instructions for the Opal 650 DD

4

To operate the damper press  the
ON/OFF button(1).
A back light will appear on the LCD
d i s p l a y   o n   t h e   t h e r m o s t a t .
 Please note that the thermostat will
operate according to the last state
before turning OFF.
Pressing the ON/OFF button while
the damper is working will shut
down the Damper.

4.1 Operating /switching OFF the damper

Please Note:

Pressing the Timer/Mode button will enable
entering to Time Operation State. To skipp
that mode press the button without stoping.

FAN

MODE

Selection the Heating or Cooling
state is done by pressing button
TIMER/MODE (2).
The operation states are:

C o o l –   f o r   c o o l i n g   m o d e  

.

H e a t -     f o r   h e a t i n g   m o d e  

.

4.2  Operating States

2

The operation states are:
START>STOP>COOL>HEAT>COOL>HEAT…

Chosing the working states is done
by pressing the FAN button(3).

4.3 Working states

FAN

MODE

3

FAN

MODE

1

T h e   w o r k i n g   s t a t e s   a r e :
The damper is open 1/3 of the
air flow.
The damper is open 2/3 of the
air flow.

RJ-11

2

3

4

1

Содержание 650-DD

Страница 1: ...D WALL MOUNTED THERMOSTAT FOR PROPORTIONAL MODULAR DAMPER OPAL RC 10 REMOTE CONTROL FOR PROPORTIONAL MODULAR DAMPER OPAL 128DD M O B THERMOSTAT FOR MOTORIZED BLADE DAMPER OPAL RC10 M O B REMOTE CONTROL FOR MOTORIZED BLADE DAMPER FLUSH MOUNT THERMOSTAT FOR PROPORTIONAL DAMPER 650 DD O P E R A T I O N I N S T R U C T I O N for ...

Страница 2: ... to set the timer Press 4 to decrease temperture and time Press 5 to encrease temerature and time FAN MODE 5 This mode enables setting the opening and closing timing Operation start Time To set start time press TIMER MODE 2 button The dis will flash Use the button to get to the stating desired time the operation time is set in 15 minutes apart After setting the start time close the unit by pressin...

Страница 3: ...screws to connect the thermostat to the Gewiss box 3 Connect the frame to the thermostat 4 Installing the Thermostat and Connecting to the Power Supply Box 2 Operation Instructions for the Opal 650 DD 4 To operate the damper press the ON OFF button 1 A back light will appear on the LCD display on the thermostat Please note that the thermostat will operate according to the last state before turning...

Страница 4: ...r System Installation When connecting power to the power supply box C 315 make sure that the green indicator light on the power supply box is on Wait 70 senconds and then set the thermostat to close position Make sure that the damper is closed If the damper opens interchange the two wires connection to the motor 3 2 Theromstat model Opal 650DD Charecteristic Fireproof plastic VO Digital display of...

Отзывы: