THE SPECIFICATIONS OF
ELECTRONIC FLUXGATE COMPASS KEC-30
1 GENERAL
1.1 Heading Accuracy
1.0
(95%)
1.2 Heading Resolution 0.1
1.3 Follow-up 45 /s r ate-of-turn
25
2.
POWER SUPPLY
2.1 Electrical
10.5
40VDC
Overcurrent, Overvoltage, Power transient and accidental reverse polarity
protection
3. (IEC61162-1)
OUTPUT/INPUT
3.1 INPUT
1
NMEA0183: RMC, GSA
Input connector is TTL, RS-232, RS-422
Input data contains: RMC, GSA
3.2 OUTPUT
1
NMEA0183 : HDG, HDT, HDM
a)
Output data includes the following three:
HDT: True heading
HDM: Magnetic heading
HDG: Magnetic heading & Magnetic variation value
Three types of outputs can select singly or output together, the optional
interval is 25ms, 100ms, 1,000ms(1s), The standard interval is 200ms,
three can output together .
The optional speed of output, the standard is 9600, the optional one is
9600, 19200 and 38400
b)
c)
Output connector is RS-232C NMEA 0183 (ver 2.0)