IMPORTANT SAFETY  INSTRUCTIONS

 

 

 

 

 

1. 

Read these instructions. 

2. 

Keep these instructions. 

3. 

Heed all warnings. 

4. 

Follow all instructions. 

5. 

Do not use this apparatus near water. 

6. 

Clean only with dry cloth. 

7. 

Do not block any ventilation openings, Install in accordance with the manufacturers  in- 

structions. 

8. 

Do not install near any heat sources such as radiators, heat registers, stoves, or  other 

apparatus (including amplifiers) that produce heat. 

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug, A polarized plug 

has two blades with one wider than the other. A grounding type plug has two blades and 

a third grounding prong.  The wide blade or the third prong are provided for your safety, If 

the provided plug does not fit into your outlet, consult an electrician for replacement of the 

obsolete outlet. 

10. 

Protect the power cord from being walked on or pinched particularly at plugs, conve- 

nience receptacles, and the point where they exit from the apparatus. 

11. 

Only use attachments/accessories specified by the manufacturer. 

12. 

Use only with the cart, stand, tripod, bracket,  or table  specified 

by the manufacturer, or sold with the apparatus. When a cart is used. 

Use caution when moving the cart/apparatus combination to avoid  in- 

jury from tip-over. 

13. 

Unplug this apparatus during lightning storms or when unused  for 

long periods of time. 

14. 

Refer all servicing to qualified service personnel. Servicing is re- 

quired when the apparatus has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid has been spilled or ob- 

jects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, 

does not operate normally, or has been dropped. 

15. 

CAUTION 

­ 

THESE SERVICING INSTRUCTIONS ARE FOR USE BY    QUALIFIED

 

SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK DO  NOT 

PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING IN- 

STRUCTIONS UNLESS YOU QRE QUALIFIED TO DO SO.

 

16. 

Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed Class 2 power 

source only.

 

17. 

ITE is to be connected only to PoE networks without routing to the outside plant. 

Содержание IPFD3TI

Страница 1: ...INSTALLATION MANUAL 3MP IP INTERIOR EXTERIOR DOME CAMERA IPFD3TI Please read this manual thoroughly before use and keep it handy for future reference...

Страница 2: ...2...

Страница 3: ...TS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is in tended to alert the user to the...

Страница 4: ...d found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equ...

Страница 5: ...from theapparatus 11 Only use attachments accessories specified by themanufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When...

Страница 6: ...troduction 6 1 1 Components 6 1 2 Key Features 7 2 Installation 8 2 1 Overview 8 2 2 Installing Camera 9 2 3 Connection 13 2 4 Resetting to the factory default settings 14 A Appendix 15 A 1 Product Sp...

Страница 7: ...frame rate Motion JPEG and H 264 videostreams The alarm input and alarm output can be used to connect various third party devices such as door sensors and alarm bells 1 1 Components This system comes...

Страница 8: ...pabilities such as enhanced video motion detection The network cameras external inputs and outputs can be connected to de vices such as sensors and relays enabling the system to react to alarms and ac...

Страница 9: ...cable additionally For its fixation on different locations please consult with aninstaller 2 1 Overview Dimension Extension Cable NO Item Description 1 RJ 45 Ethernet RJ 45 port compatible with 10 100...

Страница 10: ...portion Fig 1 2 Drill the mounting location using the supplied Drilling Guide Label Fig 2 3 Attach the surface Mount to the ceiling or wall using suitable fasteners The supplied M5x30 tapping screws...

Страница 11: ...11...

Страница 12: ...raw a circle whose diameter is 116mm on the tile You can user carton with a hole Cut the circle out of the ceiling tile Fig 2 3 Insert the bottom case into the ceiling tile and turn the locking flap t...

Страница 13: ...13...

Страница 14: ...the ground side of the alarm input and or alarm output to the G Ground connector AO Alarm Out The network camera can activate external devices such as buzzers or lights Connect the device to the AO A...

Страница 15: ...reset the network camera to the factory default settings us ing the Reset button 1 Switch off the network camera by disconnecting the power adapter 2 Press and hold the Reset button while reconnectin...

Страница 16: ...x1080 1280x1024 1280x720 960 1024x768 704x480 576 640x360 480 320x240 Video Frame Rate Max 25fps 30fps Video Streaming 25 30fps Triple Stream H 264 x 2 MJPEG x 1 Composite Out Audio Compression G 711...

Страница 17: ...oid i OS Audio 1 Input 1 Output Terminal Block Alarm 1 Input 1 Output Terminal Block Ethernet RJ 45 10 100Base T External In Out SD Card SDHC SDXC Operating Humidity 0 90 RH Non condensing Operating T...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...3MP IP INTERIOR EXTERIOR DOME CAMERA IPFD3TI 50303945A...

Отзывы: