background image

-7- 

Optional programming of the SIM card 

In order to use some of the function you want it can be necessary to program more 
contacts on the SIM card. See below: 

NB!

 To be sure programming is made in a correct way, you can check by requesting an 

SMS with SIM card settings. See page 31.Do this every time you have changed the SIM 
card settings. 

 
1.

 

Create a send list for alarms

 (see page 14). 

1)

 

Create a new contact. Name it ”SMS0” (note that 0 is zero and not the 
letter O). 

2)

 

Enter the mobile phone number for the receiver of the SMS. Save. 

3)

 

The following contacts in the send list are named SMS1, SMS2 etc,   
and the mobile numbers are entered. All numbers from SMS0 to SMS9 
can be used, in total 10 different numbers. 

 

2.

 

Set delay for activation of alarm detector (DELAY)

 (see page 17). 

1)

 

It is possible to set a delayed activation for an alarm detector.  This is 
for giving you time to deactivate the alarm before the unit is sending 
an alarm. 

2)

 

Create a new contact. Name it ”DELAYX ”.  X is the ID of the alarm 
detector you want to delay (values of 1-8 are permitted). 

i.

 

Write the numbers of seconds you want to delay in the 
telephone number field 
Example: You want alarm detector with ID no 6 to b activated 
with a delay of 45 seconds. In the name field of the contact, 
write “DELAY6” and in the field for the telephone number 
write “45”. 

 

3.

 

Activate the temperature guard (TEMP)

 (see page 20)

1)

 

Create a new contact and name it ”DEGREE”. 

i.

 

Write the alarm temperature in the telephone number field. If 
the alarm temperature is below zero degrees Celsius, add 
zero (“0”) before the temperature. For example; minus 7 
degrees C is written as “07”. 

2)

 

Create a new contact and name it  ”TEMP”.  

i.

 

In the telephone number field write  ”1” if you want an alarm 
if the temperature drops 

below

 the alarm temperature given 

Содержание GSM 9020

Страница 1: ...Ontech GSM 9020 User Manual aENGLISHa...

Страница 2: ...1234 1 0 Also the buttons to be pressed when using a telephone in tone mode not pulse is shown in this way Text in italic indicates a menu in your mobile phone for example Contacts Quotation mark shal...

Страница 3: ...the relay with SMS 13 The position of the relay after a power failure 14 Alarm 14 Wired alarm 15 Wireless alarm detectors 16 Delayed activation of alarm detector 17 Activation of relay when alarming A...

Страница 4: ...kup battery is connected 27 Short range radio extra relays 28 Reference 29 SMS from the unit 29 Alarm SMS Status SMS 29 SMS about power supply 30 SMS about GPS 30 SMS showing the SIM card settings 31...

Страница 5: ...NC Can be programmed to activate relay when alarms Wireless alarm detectors will be available during 2009 Internal temperature sensor reports temperature External temperature sensor with high accurac...

Страница 6: ...ose Contacts in the mobile phones menu a Create a new entry Name it PINCODE b In the field for telephone number enter your personal four digit number This number is the PINCODE you must enter each tim...

Страница 7: ...ble to set a delayed activation for an alarm detector This is for giving you time to deactivate the alarm before the unit is sending an alarm 2 Create a new contact Name it DELAYX X is the ID of the a...

Страница 8: ...t alarms when the ordinary power is disconnected It is possible to set a delay for this alarm 2 Create a new contract and name it POWERFAIL i In the telephone number field write the number of minutes...

Страница 9: ...ckup battery If you want to use an internal backup battery see page 26 you should install this before the physical installation The backup battery is optional and is not included in the standard packa...

Страница 10: ...ls Do not pull longer as there is a risk for the flex cable to the membrane switch to disconnect 4 Install the SIM card see picture a The upper part of the SIM card holder is moved to left until you h...

Страница 11: ...reless alarm detectors See page 28 c Switch 6 Set to ON if you do not use the short range radio and wants to turn it off in order to decrease power consumption See page 25 d Switch 8 Set to ON if you...

Страница 12: ...u shall use main power contact a professional electrician Normally Open Connect the cables to connector 2 and 3 on terminal B When activated the relay will connect the two connectors and when deactiva...

Страница 13: ...th another operation without calling up again When you have completed all operations then hang up Control the relay with SMS 1 Activate the relay send an SMS to the unit with the following text ABCD 1...

Страница 14: ...AB will start to sell different wireless alarm units which communicate with Ontech 9020 Up to 7 different alarm detectors can be connected The wireless alarm detectors planned are A Motion detector B...

Страница 15: ...or on the terminal has the following markings 0V Ground A Alarm input A B Alarm input B 12 Voltage 12 V Switch from Normally Open to Normally Closed mode Locate the DIP switch see Fig 1 Factory defaul...

Страница 16: ...ed NC mode Wireless alarm detectors In the 2009 Ondico AB will market wireless alarm detectors These can be easily connected to work together with Ontech GSM 9020 Up to 7 different detectors can be co...

Страница 17: ...evel is too high the relay is activated and turns on a pump The function is activated by adding a contact on the SIM card and name it ALARMRELAY In the telephone number field write 1 see page 7 The fu...

Страница 18: ...will be published on our web site www ondico se Tip If you want to know if the alarm is turned on or off you can check this by requesting a status SMS from the unit see page 29 When the alarm is turn...

Страница 19: ...erature sensor the second number refers to external temperature sensor if connected If not connected will be written instead If there is an asterisk for example 24 2 before the number this indicates t...

Страница 20: ...icate 1 2 degrees higher than normal due to heat produced by the relay If you wish higher accuracy 1 we recommend you to purchase the external temperature sensor Ontech Temp Sensor 9020_002 If you wis...

Отзывы: