background image

© 2009 Onset Computer Corporation 
Part #: MAN-CASE-4X 
Doc #: 7188-B

 

Protective Case (Part # CASE-4X) 

for HOBO

®

 U14-002 LCD Temp/RH Data Logger  

The Protective Case allows you to mount the HOBO U14-002 LCD 
Temp/RH data logger in wet, dusty, or condensing environments. 
The Protective Case is tested to NEMA 4X (IP65) Standards for 
protection from corrosion, wind-blown dust and rain, splashing 
water, and hose-directed water. A removable watertight fitting with 
an O-ring seal allows you to easily download data from the logger 
using a laptop or HOBO U-Shuttle (U-DT-1). 

Assembly Instructions 

The Protective Case is shipped fully assembled. This section explains 
how to install the HOBO LCD Temp/RH logger in the case, 
including the tools required for assembly. 

Items required 

To complete the assembly instructions, you will need the following items: 

 

Protective case, hook and loop tape, and desiccant pack (included in this package) 

 

HOBO LCD Temp/RH logger (Part # U14-002) 

 

External temperature or temperature/RH sensor (Part # S-THB-M00X or S-TMB-M0XX) 

 

Phillips-head screwdriver 

 

Pen, pencil, or other blunt instrument 

 

Adjustable 8 inch or 10 inch crescent wrench 

 

Utility or pocket knife 

 

Alarm relay cable (if you will be using the logger with a Remote Alarm (ARA) or  
Automatic Dialer (AVD-45) 

Steps 

1.

 

Using a Phillips-head screwdriver, remove the four screws and clear cover from the case. 

2.

 

Peel the backing from one half of the hook and loop tape, and attach the tape on the back of the 
HOBO LCD Temp/RH logger just above the battery door. 

Distributed by MicroDAQ.com, Ltd.                   www.MicroDAQ.com                   (603) 746-5524

Отзывы: