Strata Enabled Smart LiB Gauge Automatic Support Tool
11
3.
Battery Specifications Input Feature
In the Battery Specifications Input feature, you can set the target battery specifications.
1.
Enter the user’s battery manufacture and the model name.
This part is optional, entered values are saved into a log file so that it is easier to identify them later using the log data.
2.
Select the charging voltage from the pull-down list.
The charging voltage is specified in the battery datasheet. It may also be called as terminal voltage of the battery. The pull-
down list components refers to the battery profiles installed in the Smart LiB Gauge.
3.
Move the slider to enter the battery typical capacity in mAh.
It may also be expressed as design capacity or nominal capacity in the battery datasheet.
4.
Enter the Discharge Cut-off Voltage in mV.
This is the minimum cell voltage that the battery datasheet permits. If the STR-SMARTLIBGAUGE-GEVK detects the
battery discharge cut-off voltage, the board will soon stop the measurement.
Figure 12. BATTERY SPECIFICATIONS INPUT FEATURE