TX-NR414/ 515/ 616/ HT-R758/ 791/ HT-RC460/ 470/ DTR-20.4 /30.4
SCHEMATIC DIAGRAMS-11 (PART-11)
POWER SUPPLY SECTION
TX-NR414/ 515/ 616/ HT
-R758/ 791/ HT
-RC460/ 470/ DTR-20.4/ 30.4
U0080
POWER SUPPLY PC BOARD
+9VST
+12VST
STPOWER
POWERD
GND
3
1
TO BAETC-1087(PART-5)
TO BAETC-1074(PART-5)
*
T901
DTR-30.4
DTR-20.4
HT-R791
HT-R758
HT-RC470
HT-RC460
TX-NR616
TX-NR515
TX-NR414
D2
D3
HT79
HT75
HT47
HT46
T6
T5
T4
CODE
MODEL
S4
S3
S2
S1
T4AL250V
T4AL250V
T4AL250V
T4AL250V
NPT-1604M
NPT-1604M
8A 125V
8A 125V
8A 125V
8A 125V
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
NPT-1619M
NPT-1619D
---
NPT-1619M
NPT-1619D
NPT-1604D
NPT-1604M
NPT-1604D
---
NPT-1604D
NPT-1604D
NPT-1604P
NPT-1604P
---
T5AL250V
T4AL250V
10A 125V
10A 125V
12A 125V
12A 125V
D3
D2
D3
D2
T4AL250V
---
---
NPT-1604M
NPT-1604P
NPT-1604D
NPT-1604J
NPT-1604M
NPT-1604D
NPT-1604J
10A 125V
8A 125V
8A 125V
---
NPT-1619J
T4AL250V
NPT-1604M
NPT-1604P
NPT-1604D
NPT-1604J
---
HT79
HT75
HT47
HT46
T6
T5
T4
TYPE
D
M
P
J
D
M
P
J
HT79
HT75
HT47
HT46
T6
T5
T4
TYPE
D
TYPE
AC
120V
/ 60Hz
J
100V
/ 50/60Hz
220-240V
/ 50/60Hz
P
M
230V
/ 50Hz
F9002
T901
TO BAHDM-1108(PART-14) TO BAHDM-1110(PART-14)
10A 125V
10A 125V
T5AL250V
T5AL250V
T4AL250V
T4AL250V
PS2561DL1-1Y-A(Q)
PC123X8YFZ0F
BAPS-1120
KTR18EZPF6803
R9023-25
*
DE1E3KX102MB4BL01
C9019-20
Q9002-3
P/M : 47/400
D/J : 100/200
C9002
223276R2
-1B
-1A
220(1/2W)
P/M : NRL-1P5A-DC9
D/J : NRL-1P10A-DC9
(recommended resistor spec: 5k ohms/10W)
even after the power cord is disconnected from AC power source.
resistors between its terminals.
Before starting any work, please discharge C9002 by connecting
Some parts on BAPS-1120 remain high voltages
Note:
MODEL NO. TX-NR414/515/616/HT-RC460/470/HT-R758/791/DTR-20.4/30.4
SCHEMATIC DIAGRAM (PART-11) PS SECTION
2011.12.26
C9010 224K
A
V
CAUTION
AND RATING INDICATED.
ONLY WITH FUSE OF SAME TYPE
AGAINST FIRE HAZARD, REPLACE
FOR CONTINUED PROTECTION
P9002
1
2
C9015
104Z
C9012
LE103-C3.5
ECQU2A103MLC
R9015
150(1/2W)
R9003 3.3K
R9017 3.3K
J9002
C9007
DE1E3KX102MB4BL01
C9005
NC
R9022
NC
C9022
NC
C9024
104Z
C9023
104Z
L9002
RCR1010NP-100M
C9013
220/25
L9005
BLM18PG181SN1D
L9004
BLM18PG181SN1D
L9003
NC
E9001
2 3 4
1
C9014
102J
D9009
KDS4148U
D9010
KDS4148U
JL901A
NSCT-5P876
5
4
3
2
1
C9025
NC
C9026
NC
C9011
104K
R9004
470
C9021
471J
R9021
47
R9002
4.7K
D9004
RF301B2STL
R9016
0
C9006
470/25
C9017
NC
R9019
NC
R9020
NC
R9011
NC
R9012
NC
R9007
68K
R9006
470K
R9008
150K
Q9004
KIA431A
2
3
1
R9009
100
C9004
1000/25
D9008
RB050M-30
Q9005
KRC102S
R9005 1.8K
R9018
NC
Q9003
3
2
1
4
D9011
KDS4148U
ARE CRITICAL FOR SAFETY.
+
* THE COMPONENTS IDENTIFIED BY MARK
* VOLTAGE (MEASUREDWITHVOLTMETER) ISDCVOLTAGE. (NO INPUT SIGNAL)
* ELECTROLYTIC CAPACITORS ( ) ARE IN uF/WV.
* ALL CAPACITORS ARE IN pF/50WV UNLESS OTHERWISE NOTED.
* CIRCUIT IS SUBJECT TO CHANGE FOR IMPROVEMENT.
REPLACE ONLY WITH PART NUMBER SPECIFIED.
CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST
A LENT, E POUR UNE PROTECTION PERMANENTE,N'UTILISER
QUE DES FUSIBLES DE MEME TYPE. CE DARNIER EST
INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE.
THAT THE FUSE USED IS SLOW OPERATING TYPE
RATING REFER TO THE MAKING ADJACENT TO THE SYMBOL.
THIS SYMBOL LOCATED NEAR THE FUSE INDICATES
FOR CONTINUED PROTECTION AGAINST FIRE FUSE
HAZARD,REPLACE WITH SAME TYPE FUSE. FOR FUSE
AFIN D'ASSURER UNE PROTECTION
PERMANENTE CONTRE LES RISQUES
D'INCENDIE, REMPLACER UNIQUEMENT
PAR UN FUSIBLE DE MEME TYPE
ET CALIBRATION COMME INDIQUE.
ATTENTION
V
A
C9019
P9001A
2
1
C9020
R9025
R9024
L9001
ELF15N004A
3
4
1
2
C9018
LE104-MX
C9001
LE104-MX
D9002
P6SMB200A
D9003
US1K
D9001
S1WB(A)60B
R9010
NC
D9014
UDZS6.8B
R9001 10K
D9017
UDZS7.5B
C9008
105Z
D9016
UDZS7.5B
C9016
103K
R9014
100K
D9013
UDZS6.8B
C9009
102J
D9015
UDZS7.5B
R9013
4.7K
Q9002
3
2
1
4
R9023
R9125
NC
F9001
T1AL250V
F9002B
NC
F9002A
NC
F9002D
F9002C
E9002
2
1 3 4 5
J9003
TA5
J9004
TA7.5
C9002
RL9001
3
4
1
2
C9003
10/50
D9012
UDZS36B
T9001
NPT-1621S
1
3
6
5
7
8
9
10
11
12
Q9001
MIP2M40MSSCF
5
DRAIN
7
SOURCE
8
LS
1
VDD
2
FB
3
SO
4
VCC
D9006
M1FL20U
D9005
NC_ES1D
A
1
2
3
4
B
C
D
E