5
Components:
Listening
1. Set the VOLUME control to minimum and press the power switch (POWER).
2. Set using the INPUT button on the desired audio source, each time the button is pressed, it changes
the audio source input.
3. Adjust the volume of the amplifier by using the VOLUME of the control.
Protection
Troubleshooting
The device has a sophisticated protection circuit against the short circuits, distinguishing itself with the
simultaneous flashing of all LEDs for a few seconds, in this case must be unplugged the power cord and leave
unplugged for at least 15 minutes.
Symptom
Cause
Remedy
No power
supplied to unit
Inputs
The amplifier has four RCA inputs (BYPASS, VIDEO, TUNER, SACD) for various audio components and one
XLR imput, the inputs VIDEO, TUNER, SACD have the same function, while the input BYPASS allows to use
the amplifier only as a power amplifier, not the preamplifier stage.
Incorrect operations are often mistaken for trouble and malfunctions. If you think that there is something wrong
with this component, check the points below. Sometimes the trouble may lie in another component. Investigate
the other components and electrical appliances being used.
If the trouble cannot be rectified even after exercising the checks listed below, ask your nearest ONIX authorized
service center or your dealer to carry out repair work
.
Power plug is disconnected from outlet Check that power cord and insert the plug
securely into outlet
No sound
Connecting cords are disconnected
from terminals, or connected
incorrectly
Check if connections between external device
and the amplifier are connected correctly.
No sound from
one speaker
Connecting cords or speaker cords
are disconnected on the side.
Verify that the cables between amplifier and
speaker are well- connected according to the
different polarity.
The position of the input selector does
not correspond to the component to be
played back.
Check if the LED of the input selector
corresponds to the input source that you want
to listen.
Power transistor Sanken C3264/A1295 for every channel; Filter capacitor Nichicon “Super Through”
4 x 10.000uF/80V; 4 x MUR Ultra fast rectifier diodes; two high efficiency toroidal trasformers supplying power
to two channels independently 600VA; Motorized Alps “Blue Velvet” potentiometer.