2. Speed selection
Med
Low
High
Speed / Application
Filtration and
water circulation
Cleaning with a
suction cleaner
Backwashing
filter.
Operating some
water features such
as jets or waterfalls.
Solar heating
The Onga Eco800 comes pre-programmed with the following default speeds:
1450RPM
2400RPM
2800RPM
Press for low speed
Press for medium speed
Press for high speed
Off button
Press to turn power on/off.
If power is removed, motor will return to the last speed selected when power is restored.
Motor will remember ON/OFF state.
3.Variable Speed Adjustment
If the default speed settings do not perfectly match the particular installation. They can be adjusted as follows.
1. , or
Press and hold button corresponding to speed you wish to change.
Hold for 3 seconds and a light should begin to flash.
2.
To decrease speed by 50rpm increments with 1000rpm as the
minimum limit
Med
SET
Low
-
High
+
Low
-
High
+
To increase speed by 50rpm increments with 2850rpm as the
maximum limit
3.
Med
SET
To save the current speed setting and return to normal operation mode
Will cancel the change and revert back to the original speed and
return to normal operation mode
Med
SET
Low
-
High
+
+
+
Holding all 3 buttons for 3 seconds will reset the speeds to default
9
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:35 AM