Specifications

Ultrasonic frequency

42KHz

Tank

SUS304 stainless steel

Housing

Stainless steel

capacity

800ml

Time control

0-30 minutes,18 cleaning time optional, digital control

Input voltage

AC100-120V,50/60Hz OR AC 220-240,50/60HZ

Ultrasonic Power

35W

Dimension

Tank: 154*88*65mm
Overall: 180*110*128mm
Package: 235*170*180mm

Weight

N.G. :1 kg

G.W. :1.3kg

Removal of common fault

No.

Problems

Reasons

Solutions

1

Ultrasonic cleaning
does not work

A. The power lord is

not connected;

B. The fuse is burned;

C. High frequency wire

is disconnected or not

well-connected;

D. The circuit problem

of transducers;

E. Other reasons.

A.Check the power connection and plug
the power lord;
B.Change the burned fuse with a good
one of the proper voltage;
C.Connect or change the high
frequency wire;
D.Check the circuit or consult our
after-sale service department;
E.Find out the defective component,
replace it or ask our after-sale service
department for a new circuit board.

2

The time setting
does not work

A.The timer is broken;
B.Other reasons

A. Reset the power;
B. Change the timer or digital control
panel;
C. Consult the after-sale service
department;

3

Bad cleaning effect

A. Prolong the cleaning time;
B. Adjust the cleaning solution to a
best cleaning level;
C. Choose the right detergent;

4

Leakage of the
electricity

A. Ensure that the ground wire is
well-connected;
B. Check whether the ground wire is
loose and make it well-connected.

5

Other problems

Consult the after-sale service
department

Содержание OZL-800

Страница 1: ...ess steel tank Thank you for purchasing this ultrasonic cleaner Please take some time to read these operating instructions before use and keep them for future reference Failure to follow these instructions may lead to serious artificial damages to the product ULTRASONIC CLEANER OZL 800 USER MANUAL ...

Страница 2: ... and other militaria Ultrasonic cleaning is not recommended to be used to clean the following gemstones Opal Pearl Emerald Tanzanite Malachite Turquoise Lapis and Coral Ultrasonic cleaning is based on the cavitation effect caused by high frequency ultrasonic wave vibration signal in the fluid Microscopic bubbles are formed and then implode violently causing the cavitation which create an intense s...

Страница 3: ... with the power cord the red indicator will turns on and the LED screen will display 180 B Press the TIME button to switch the cleaning time in the following time circulation 90 120 150 180 210 240 270 300 330 360 540 720 900 18 21 24 27 30 90 18 cleaning time in total C Press ON OFF button once to make the machine start cleaning The blue ultrasonic indicator turns on the setting time starts count...

Страница 4: ...nnection and plug the power lord B Change the burned fuse with a good one of the proper voltage C Connect or change the high frequency wire D Check the circuit or consult our after sale service department E Find out the defective component replace it or ask our after sale service department for a new circuit board 2 The time setting does not work A The timer is broken B Other reasons A Reset the p...

Отзывы: