VI. General Assembly Instructions
Do NOT use hook on motor to lift unit.
With all assemblies, make sure rectangular air outlet is oriented on Fan/Blower housing as you
are looking down as in Fig. 1A or facing it as shown in diagrams. This is very important.
Before you start, make sure you have cut and placed the provided gasket material on top and bottom of
the Fan / Blower housing and the Cone as shown in the diagrams. Then determine which direction you
want your filter to hang and which direction your ductwork will enter the collector.
Bolt Fan / Blower housing to Cyclone barrel, Then bolt Motor to Fan/Blower housing. Put Cone up on wall bracket and orient
holes. Lift assembled unit onto cone making sure proper holes are lined up. Bolt unit to bracket, then finish bolting barrel to
cone. Screw Motor Cowling to Motor.
See below for complete instructions.
Assemble stand then bolt cone and barrel to stand. Lay stand on its’ side then bolt Fan / Blower Housing and Motor to the
Barrel. Then carefully lift system into position. Screw Motor Cowling to Motor.
See below for complete instructions.
Assembling the Dust Collector to Wall Bracket.
Assembling the Dust Collector to Stand.
1. Wall Bracket Method
There are two methods for assembling this unit:
2. Stand Method
See Pg. 7 for instructions on mounting the wall bracket to the wall.
See Pg. 12 for instructions on assembling stand.
When units are assembled, they are very heavy and top-weighted. Make
sure you have adequate assistance and study equipment when you are
assembling them.
1. Attach gasket (RGZ025050) to the top of cyclone cone (SCX002109). Make sure you apply it inside the bolt holes around the cone
top and it is important that you do not leave any gaps where the ends of the gasket meet.
1. Use the above instructions except attach the cone and barrel to the stand while upright, then lay the stand down on its’ side. Attach
the fan housing and motor while upright then lay them on their side to attach them to the barrel. With adequate help, lift the unit back up
into position then attach the Motor Cowling.
2. Lift cone onto wall bracket (SMS300021) making sure to align the holes in the bracket with the holes in the cone.
5. With the help of another person, lift the assembled unit up onto the cone, aligning the holes in the bottom of the barrel with the holes
in the cone, making sure you have the barrels inlet in the proper position for your layout. Attach the unit to the bracket using the (3) 3/8
x 1” Hex bolts (AFS015700) with a washer on top of barrel rim and a washer below the bracket (AFW190000) and fasten with a whiz
nut (AFT000004). Now fasten barrel to cone with (9) 5/16 bolts (AFB155190) with a washer on top and bottom (AFW180000) and a
whiz nut (AFT155175).
3. Attach Fan Blower Housing (BHX001800) to barrel (SXI002108) on floor. Put gasket material around top rim of barrel, outside of
the bolt holes, again making sure that there is no gap where the ends meet. Make sure that the housing’s outlet is oriented in the
direction that fits your shop layout and the pre-installed nuts are on the underside of the top. Attach barrel with (8) 5/16 Flange bolts
(AFB155175) and (8) 5/16 washers (AFW180000). You will not need any nuts. They are already installed in the barrel. Attach gasket to
top of blower housing inside of the bolt holes.
4. Attach motor (BXI001803) to the blower housing using (7) 5/16 flange bolts (AFB155175) and washers (AFW180000). No nuts are
needed as they are already built into the blower housing.
The motor is very heavy and cumbersome! Be sure to have adequate
help to lift it up! Be extremely careful that you do not pinch any of the electronics under the plate.
6. Attach Motor Cowling (BHX001803) to Motor with (4) Sheet Metal Screws (AFS010075)