Oneida Air Systems 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors Скачать руководство пользователя страница 5

III.  General Specifications & Fan Performance Curves

4

7.5hp Fan Performance Curve

5hp Fan Performance Curve

O.A.S. 2002

c

Physical and Electrical Data for 5 and 7.5hp Direct Drive Systems.

5hp 1220 max cfm - 2250 cfm w/ typical ductwork
7.5hp 2900 max cfm - 2500 cfm w/ typical ductwork

System Performance

Height w/ 55 Gal. Drum: 132”
Footprint: 8.5’ x 3’
Fan Wheel diameter: 16” Air Foil design
Cyclone Inlet: 10”

System Dimensions

TEFC 60 Hz Motor - Single Phase
Insulation Class: F4
Voltage: 230
Amperage: 19.8
Made in U.S.A.

Integral Fan Blower - 5hp

TEFC 60 Hz Motor - Three Phase
Insulation Class: F4
Voltage: 208 - 230 / 460
Amperage: 19.6 - 18.4 / 9.2
Made in U.S.A.

Integral Fan Blower - 7.5hp

Standard: 8 Tube Filters - 5hp, 10 Tube Filters - 7.5hp
Needle felted polyester filter media BIA ZHI / 487 test -
Rated G
Captures 99% of test material over 20 microns
Captures 99.5% of test material between 0.2 - 2.0 microns
@ 11 fpm face velocity

Tube Filter Bags

2 Pleated Cartridges - 260 sq. ft.
Spun Bonded polyester BIA ZH1 / 487 test - Rated C
Captures 99.99% of test material over 20 microns
Captures 99.9% of test material between 0.2 - 2.0 microns
@ 11fpm

External Cartridge Filters (2)

55 Gal. Steel Drums
Large dust bins available

Dust Bin

Angle iron stand for free-standing unit
Silencers available
Magnetic Motor Starters

Options

5 - 7.5 HP Direct Drive Owner’s Manual

0

2

4

6

8

10

12

Static Pressure (In-H2O)

CFM

- Fan Curve

14

16

18

3000

2500

2000

1500

1000

500

0

3500

4000

3350

2875

2400

2025

1725

1400

1100

760

5hp System - 2000 CFM @ 8” Static Pressure

0

2

4

6

8

10

12

Static Pressure (In-H2O)

CFM

- Fan Curve

14

16

18

3000

2500

2000

1500

1000

500

0

3500

4000

3500

3100

2725

2440

2100

1875

1590

7.5hp System - 2700 CFM @ 8” Static Pressure

Содержание 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors

Страница 1: ...5 7 5 HP Direct Drive Cyclonic Dust Collectors Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Страница 2: ...e ofContents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 System Start Up Information Di...

Страница 3: ...nual 4 Have a licensed electrician check current draw on motor with all gates open Current draw should not exceed maximum motor amperage OAS is not responsible for destroyed motors Caution The Direct...

Страница 4: ...gases carbon monoxide can be drawn into the shop from furnaces water heaters or other appliances 2 External Cartridge Filters 3 External Tube Filter O A S 2002 c 5 7 5 HP Direct Drive Owner s Manual...

Страница 5: ...filter media BIA ZHI 487 test Rated G Captures 99 of test material over 20 microns Captures 99 5 of test material between 0 2 2 0 microns 11 fpm face velocity Tube Filter Bags 2 Pleated Cartridges 260...

Страница 6: ...39 1 4 62 73 1 8 12 12 32 1 8 O D of Mounting Ring 69 875 24 1 4 Bolt Holes 30 3 8 10 031 I D 7 64 I D 1 25 Flange Tube Filters Height for 8 bags Other heights available 131 w 55 gal steel drum 105 No...

Страница 7: ...race for Cyclone Angle Ring to sit on 1 Choose the system orientation plenum can be on the right or the left of the cyclone Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cros...

Страница 8: ...iron ring will be on top of the cross bars of the stand Put bead of silicone around inside edge of flange on the cyclone cone Then put bolt through flat washer then bolt through holes in both flanges...

Страница 9: ...ocedures could result in serious injury or death Disconnect all power and discharge all capacitors before servicing Install and ground per local and national codes Consult a licensed electrician with...

Страница 10: ...n plastic bucket and tube filter to fit properly underneath A well sealed plywood box will make a good plenum for air distribution through the tube filters Use plywood for the plenums Cut 12 dia holes...

Страница 11: ...ring the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock material down WARNING A...

Страница 12: ...licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw 11 Top View Outlet Inlet O A S 2002 c 5 7 5 HP Direct Drive O...

Страница 13: ...5 and 7 5hp direct drive dust collectors do not come wired or with an on off switch Because of the voltage and amperage requirements of the system an industrial switch must be used OAS offers Square...

Страница 14: ...nd as a sealant Check for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check fo...

Страница 15: ...elow 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an e...

Страница 16: ...warrants In no event shall O A S s liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of...

Отзывы: