background image

O.A.S. 2005

c

3HP High Vacuum Owner’s Manual

11

X.  Accessories

Dust Bin Options -

 

(Must Order Custom Mounting Stand.)

2. Hoppers -

Large capacity hoppers from .5 cu. yd. to 3 cu. yd.

3/16” reinforcing angle for added support - 3/16” plate body is 100% continuously

MIG welded on inside - 3/8” rear cross brace angle (not 3/16”) - three 3” base

channel - All angles are structural not formed.

3. Air Locks -

Rotary air locks provide an alternative to an air tight dust bin for larger

volume capacity and less maintenance.

Example - A 10” air lock will drop 1.85 cu. ft. / rev. of material.

1. Multiple Drums -

Custom order the System Mounting Stand for multiple drums or hoppers.

Stand widths will vary depending on dust container.

Magnetic Motor Starters - 

 The 3hp high pressure dust collectors do not

come wired or with an on/off switch. Because of the voltage and

amperage requirements of the system, an industrial switch must be

used.

OAS offers Square “D” Full Voltage Non-Reversing across the Line

Starters, Nema Type 1 Enclosure with Start/Stop in cover, and class 10

overload. Industrial switches can also be purchased through your local

electrician. Due to varying electrical codes, OAS cannot specify exact

wiring requirements. When wiring the collector you should always hire

a licensed electrician.

Bin Level Monitor - 

Provides level sensing for dry bulk solids. The monitor

operates by using a 1 rpm synchronous motor to rotate a paddle.

 When paddle rotation is impeded by material surrounding it, the motor

is de-energized and triggers a SPDT snap switch. The snap switch can

be used in conjunction with a motor starter to turn equipment off or

provide alarm functions.

ABX000000

The BAG Gripper provides the ability to use convenient plastic bags inside

your dust drum. It provides a constant, negative pressure on the outside

surface of the plastic bag that keeps it pulled tight against the sides of the

dust drum. Can be used with 35 and 55 gal. barrels. Must be wired into

your system.

The BAG Gripper

Содержание 2005c3HP

Страница 1: ...3HP High Vacuum Dust Collector Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Страница 2: ...t Table of Contents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 System Start Up Informa...

Страница 3: ...Caution The Dust Collector Fan Blower is heavy Handling and installation should always be performed by experienced and trained personnel who have experience with rotary equipment In addition to the f...

Страница 4: ...Vacuum Owner s Manual 3 Pleated Cartridge Filters Do not remove fabric straps from cartridge Removable Dust Container Removable 55 Gal Metal Chip Dust Bin 3hp Integral Fan Blower Angle Iron Stand Fle...

Страница 5: ...Spun Bonded polyester BIA ZH1 487 test Rated C Captures 99 99 of test material over 20 microns Captures 99 9 of test material between 0 2 2 0 microns 11fpm External Cartridge Filter 55 Gal Steel Drums...

Страница 6: ...2 7 1 4 36 75 3 4 111 7 8 12 62 30 7 8 10 031 I D 7 64 I D 1 25 Flange For Minimum Mounting Heights with 55 gal drum 26 1 8 O D of Mounting Ring Bolt Holes 24 7 8 18 56 Outlet Size 56 7 3 4 14 1 8 18...

Страница 7: ...cuum Owner s Manual V Angle Iron Stand Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cross bar on the cyclone stand goes in the back so that the dust bin can slide out 55 Gal...

Страница 8: ...gral Fan Blower Angle Iron Stand Outlet Inlet Elbow Square to Round Cone Cyclone Clamp Ring VI Assembly Instructions Cyclone Barrel Air Inlet Fan Blower 1 1 Orient the blower housing to match the stan...

Страница 9: ...ground per local and national codes Consult a licensed electrician with questions or if repairs are required Electrical Connections A All wiring fusing and grounding must comply with National Electri...

Страница 10: ...tom dust pan before or during the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock...

Страница 11: ...tor 230v 14 5 amps TEFC Wiring should always be done by a licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw Top...

Страница 12: ...must be used OAS offers Square D Full Voltage Non Reversing across the Line Starters Nema Type 1 Enclosure with Start Stop in cover and class 10 overload Industrial switches can also be purchased thro...

Страница 13: ...ort or too small a branch line See branch line diameter chart in ductwork guide Be sure that your filter is clean See filter cleaning directions Filter Clogging Caused By Air leakage between cyclone a...

Страница 14: ...below 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an...

Страница 15: ...York County of Onondaga Oneida Air Systems shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of o...

Страница 16: ...3HP High Pressure Owner s Manual 15...

Отзывы: