2.2 Cleaning and Maintain for Cooling pad
In order to ensure cooling effect, the cooling pads should be cleaned regular (suggest
cleaning every year). When cleaning cooling pads, the hydraulic pressure can not be too
high and the temperature should not be more than 40 degrees centigrade. It is
recommended that using soft brush to wipe off the dust on the cooling pad. After
cleaning, the cooling pads should be dried off and put back to cooler. If the cooler does
not work for a long time, in order to avoid damaging the cooler due to weather condition
like freezing, and avoid breeding mosquitoes and other insects, the water tank should be
drained and turn on the cooler by pressing “ON/OFF” button to dry off the cooling pads.
Shut off the cooler after cooling pads are dried off

.

There is a hole for uncovering

By pulling out upward

to refill water steadily.

After removed the supporting rod for cooling pad and
air-inlet grille, the cooling pads can be pulled out.

3. Construction Diagram of Evaporative Air Cooler

MO-36E-18Y

3

4

Back Cooling
Pad

Top Cover

Control Panel

Swing

Air outlet

Outlet decoration

Front Shell

Water Level Indicator

Water Tank

Caster

Side Cover

Water Filling
Tray

Dust Proof Net

Drain Plug

Back Cover

Plastic Screw

Supporting Rod for Cooling Pad

side Cooling Pad

Cleaning the cooling pads by water
and wipe off the dust by soft brush.

Содержание MO-36E-18Y

Страница 1: ...MO 36E 18Y Installation Operation Manual ...

Страница 2: ...ions and Functions 1 2 1 For Control Panel and Remote Control 1 2 2 Cleaning and Maintain for Cooling pad 2 3 Construction Diagram 4 4 Troubleshooting Guide 5 5 Product Dimension 6 5 Technical Information 6 6 Circuit diagram 8 7 Exploded view 8 9 ...

Страница 3: ...ater tank need to be refilled In the case where the wind speed is high when the Cool button is pressed the cooler will drop to the lowest speed for 80 seconds before resuming the speed previously set Swing Press the Swing button on the control panel or remote control to have the vertical louvers swing automatically and the unit will enter the Swing mode with indicator light on Press again and the ...

Страница 4: ...reeding mosquitoes and other insects the water tank should be drained and turn on the cooler by pressing ON OFF button to dry off the cooling pads Shut off the cooler after cooling pads are dried off There is a hole for uncovering By pulling out upward to refill water steadily After removed the supporting rod for cooling pad and air inlet grille the cooling pads can be pulled out 3 Construction Di...

Страница 5: ...ay Repair or replace the control panel with another of the same model 5 6 4 The pump functions but it is not cool enough Air ventilation chamber is not large enough Filter pads are clogged or dirty Clean or replace the filters Check the parameters of the replacement parts The filter pads are dry or contain insufficient water while the air cooler is working Check the water distribution system to de...

Страница 6: ...Y Air Volume 9216 CFM Voltage Frequency 110 V 60 Hz Power 128 W Water tank capacity 8 45 US gal Overall dimension 12 6x16 54x47 24 in No of Cooling pad 3 PCS Net weight 22 00 lb Area Coverage 322 92ft 7 47 24 in 8 Circuit diagram 8 Exploded view 8 12 6 in 16 54 in ...

Отзывы: