Page 13 Total 16
the stop block of the cassette mechanism and thus affect its work life.
3
)
Regular inspection on the connection of different parts and fixing loosened screws
to avoid mechanical failures after long time operation.
4
)
The casing of the turnstile must have reliable earthing, so as not to avoid electric
shocks.
5
)
Strictly prohibit plugging in or out of the sockets when the turnstile is electrified,
which will damage the control circuit.
6
)
The product is offered with free repair guarantee for one year, and the repair after
free period will be charged with maintenance cost only.
7
)
The technical changes or remodeling of our products will be without further notice.
8
)
We heartily welcome suggestions for improvement from all the users of our
products.
9
)
When errors occur in this product, please contact our after-sales department or our
local branch in time, and we will send technicians to deal with the problem. Don’t
disassemble the equipment casually, which might damage internal structure of the
equipment.
Attachment
Attachment
Attachment
Attachment 1
1
1
1:::: Communication
Communication
Communication
Communication Protocol
Protocol
Protocol
Protocol
Physical
Physical
Physical
Physical interface
interface
interface
interface::::
Using the RS232 communication standard 8-bit asynchronous data to transfer
formatRS232 communication using the standard 8-bit asynchronous data transfer format
Data transfer format list below
:
Baud Rate: 9600
Duplex: half-duplex
Start Bit: one
Data Bit: eight
Parity: none
Stop Bit: one