background image

Installing the Host Cable Adapter

:

 

1. 

Insert the Host Cable Adapter into a PCIe x8 or x16 add-in card slot.  Make sure that the card is well seated and 

tighten the screw on the front backet. 

 

2. 

Attach the cable by first pulling back on the retractor ring. With the keyed slot aligned with the connector key ridge on 

the slot cover, insert the cable connector into the cable port connector on the board until the cable locks in place.

 

3. 

The connectors on either end of the PCIe x8 cable are identical. Each connector is equipped with a

 

retractor to allow 

the connector to be locked into place.

  

 

    Retractor 

on 

Cable 

Connector 

 

Alignment

 

grooves

 

Retractor ring

 

 

 

 

 

 

 

 

 

 

 

 

4.  Attach the other end of the cable to the upstream port connector of the ELB in the expansion enclosure. To link to a 

second expansion enclosure, connect a second cable from the downstream port connector on the ELB of the first 

expansion enclosure to the upstream port connector on the ELB of the second enclosure.

 

 

Removing the Host Cable Adapter

 

1.  Remove the cable by pulling on the green retractor ring which releases the locking mechanism. 

2.  Loosen and remove the front bracket screw before removing the Host Cable Adapter from the card slot.  

 

One Stop Systems, Inc.                                                                                                               Host Cable Adapter User Manual  
Rev. A    

 

 

 

      3 

 

Содержание OSS-PCIe-HIB2-x8-H

Страница 1: ...st Cable Adapter User Manual Rev A PCIe x8 Host Cable Adapter User Manual OSS PCIe HIB2 x8 H OSS PCIe HIB2 x8 T 2235 Enterprise Street Suite 110 Escondido CA 92029 Phone 760 745 9883 Fax 760 745 9824...

Страница 2: ...unpacking verify that all items listed in the packing list are present 3 Inspect the equipment for shipping damage 4 Save all packing material for storage or return shipment of the equipment 5 For re...

Страница 3: ...a retractor to allow the connector to be locked into place Retractor on Cable Connector Alignment grooves Retractor ring 4 Attach the other end of the cable to the upstream port connector of the ELB i...

Страница 4: ...5W maximuml 3 3V 2 27A Operating Environment designed to meet the following conditions Temperature Range 0 to 50 C 32 to 122 F Relative Humidity 10 to 90 non condensing Shock 30g acceleration peak 11...

Страница 5: ...SEL6 Output Swing Control Output De emphasis Adjustment SEL5_ A D SEL6_ A D De emphasis 0 0 0dB 0 1 2 5dB 1 0 3 5dB 1 1 4 5dB SEL3_ A D SEL4_ A D Swing 0 0 1x 0 1 0 8x 1 0 1 2x 1 1 1 4x Equalizer Sele...

Страница 6: ...GND Ground GND Ground 5 SMCLK SMBus clock JTAG2 TCK 6 SMDAT SMBus data JTAG3 TDI Test Data Input 7 GND Ground JTAG4 TDO Test Data Output 8 3 3V 3 3 V power JTAG5 TMS Test Mode Select 9 JTAG1 TRST Test...

Страница 7: ...und 43 GND Ground PERp6 44 GND Ground PERn6 Receiver differential pair Lane 6 45 PETp7 GND Ground 46 PETn7 Transmitter differential pair Lane 7 GND Ground 47 GND Ground PERp7 48 PRSNT2 Hot Plug presen...

Страница 8: ...pair or replace the defective parts at the purchaser s cost and deliver the defective parts to the purchaser This limited warranty shall not apply if the product has been misused carelessly handled de...