background image

4. Technical Information 

 

4.a. LEDs  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

LED # 

Function 

CR2 

Tx pair, Lane 0 (from card edge) 

CR3 

Rx pair, Lane 0 (from cable) 

CR4 

Tx pair, Lane 1 (from card edge) 

CR5 

Rx pair, Lane 1 (from cable) 

CR6 

Tx pair, Lane 2 (from card edge) 

CR7 

Rx pair, Lane 3 (from cable) 

CR8 

Tx pair, Lane 3 (from card edge) 

CR9 

Rx pair, Lane 2 (from cable) 

 

Power LED 

PCIe Lane Status LEDs 

 

 

Power and 

Cable present 

LEDs 

CR2 CR4 CR6 CR8 

CR3 CR5 CR7 CR9 

Cable present 

LED 

4.b. Block Diagram 

 

LVPECL 

Clock Buffer

 

Downstream  

x4 PCI Express  

Cable Connector 

Upstream  

x4 PCI Express  

Card Edge Connector 

PCIe Signal 

Redriver 

PCIe Signal 

Redriver 

x4 PCIe Tx 

x4 PCIe Tx 

Clock* 

Clock* 

LEDs 

Cable Present/ Pwr 

 

x4 PCIe Rx 

x4 PCIe Rx 

CPRSNT# 

+3.3v 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

LEDs 

PCIe lane 

status

*Clock direction shown in Host configuration 

One Stop Systems, Inc.                                                                                                             OSS-KIT-EXP-4500 
Rev. A    

 

Page 7 

 

Содержание Max Express OSS-KIT-EXP-4500

Страница 1: ...One Stop Systems Inc Host Cable Adapter User Manual Rev A User Manual PCIe x4 Host Cable Adapter HIB2 OSS KIT EXP 4500...

Страница 2: ...onceptual architecture 4 2 Specifications 2 a Host interface board 5 2 b Host expansion board 5 3 Installation Instructions 3 a Connecting PCIe cable 6 3 b Removing PCIe cable 6 3 c Installation instr...

Страница 3: ...ard HIB2 sits in the host machine and cables to the Host Expansion Board HEB2 The Host Expansion Board site in a CPCI CPCE Chassis Host interface board PCIe x4 cable Host expansion board One Stop Syst...

Страница 4: ...3 3v One Stop Systems Inc OSS KIT EXP 4500 Rev A Page 4 Slo Al low profile height 3 35 PCIe x4 Connect Power on Cable Ready 2 713 Clock direction shown in Host configuration 1 c Host Expansion Board...

Страница 5: ...Operating Environment Temperature range 0 to 50C 32 to 122F Relative Humidity 5 to 90 non condensing Shock 5 17 Hz 0 5 double amplitude displacement 7 2000Hz 1 5g acceleration Agency Compliance Design...

Страница 6: ...backplane to an ATX power supply separate from the host system power supply 3 Insert the HIB2 x4 in target mode in the PCIe connector on the test backplane next to the ATX connector 4 Insert the PCIe...

Страница 7: ...om cable Power LED PCIe Lane Status LEDs Power and Cable present LEDs CR2 CR4 CR6 CR8 CR3 CR5 CR7 CR9 Cable present LED 4 b Block Diagram LVPECL Clock Buffer Downstream x4 PCI Express Cable Connector...

Страница 8: ...Test Clock 7 GND Ground JTAG4 Host Mode TDO Test Data Output Target Mode Test Clock 8 3 3V 3 3 V power N C Not connected 9 N C Host Mode Not connected Target Mode Test Power On N C Not connected 10 3...

Страница 9: ...n3 Differential PCI Express transmitter Lane 3 5 A13 GND Ground reference for PCI Express transmitter Lanes A14 CREFCLK Differential 100MHz cable reference clock A15 CREFCLK Differential 100MHz cable...

Страница 10: ...e power return B18 CWAKE Power management signal for wakeup events optional 1 3 B19 CPERST Cable PERST Notes 1 Optional signals that are not implemented are to be left as no connects on the board side...

Страница 11: ...12 A14 CREFCLK Differential Pair CREFCLK A14 A15 CREFCLK CREFCLK A15 A17 SB_RTN Hook up Wire SB_RTN A17 A18 CPRSNT Hook up Wire CPRSNT A18 A19 CPWRON Hook up Wire CPWRON A19 B2 PERp0 Differential Pair...

Страница 12: ...ock from the host system to the remote system SB_RTN Side Band ReTurN return path for single ended signals from remote systems CPRSNT Cable PReSeNT Indicates the presence of a device beyond the cable...

Страница 13: ...One Stop Systems Inc OSS KIT EXP 4500 Rev A Page 13 5 Ordering Information OSS KIT EXP 4500...

Отзывы: