One Stop Gardens 94593 Скачать руководство пользователя страница 6

SKU 94593

        For technical questions, please call 1-800-444-3353

Page 6

6.

Hold the handle of the Pneumatic Shears with both hands, release the safety

latch on the Trigger Lever (22) and pull the Trigger Lever to begin the cut.

The blades will retract once the cut is complete.

7.

When cutting is complete, push the Blade Safety Latch (38) up to lock the

blades so they cannot close.

8.

Disconnect the air supply hose.

Maintenance

1.

After each use, remove the air hose and wipe the Pneumatic Shears with a

clean cloth to remove any dirt and grease buildup.

2.

To maintain tool life, always lubricate the air line by adding a few drops of

pneumatic tool oil to the air line before each use. You can also install the
automatic oiler-filter system, as illustrated on Page 5.

3.

Before each use, drain water out of the air compressor tank and

condensation from the air lines. Refer to the Air Compressor Operator’s
Manual.

Manual Tool  Lubrication

1.

Disconnect the Pneumatic Shears from the air supply and turn it so the Air

Inlet (12) fitting is facing upward.

2.

Hold the Trigger Lever (22) in and place one teaspoon of pneumatic tool oil

into the air inlet (use SAE #10 weight oil if air tool oil is not available). Holding
the Trigger Lever in helps circulate the oil in the air motor.

3.

Connect the Pneumatic Shears to the air supply and cover the air outlet with

a towel.  Run for a few seconds. Excess oil with be blown out.

Troubleshooting

Problem

Probable Cause

Possible Solution

Shears do not cut
when Trigger
Lever pressed.

1.

 

Insufficient or no air
supply.

2.

 

Problem or leak in
air hose.

3.

 

Blade Safety Latch
(38) is in the lock
position.

1.

 

Fill air tank or turn
compressor on.

2.

 

Check air hose
connections.

3.

 

Move the Blade
Safety Latch to
unlock.

Blades are not
cutting properly.

1.

 

Loose Bolt (32).

2.

 

Blades are dull.

3.

 

Insufficient air
pressure.

1.

 

Tighten Bolt (32).

2.

 

Have Blades
sharpened by a
qualified technician.

3.

 

Check air supply
tank for 90 PSI
pressure.

Содержание 94593

Страница 1: ...bor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 94593 Due to continuing improvements actual product may differ slightly from the product described herein ...

Страница 2: ...area Do not let them handle machines tools or extension cords 4 Store idle equipment When not in use tools must be stored in a dry location to inhibit rust Always lock up tools and keep out of reach of children 5 Use the right tool for the job Do not attempt to force a small tool or attachment to do the work of a larger industrial tool There are certain applications for which this tool was designe...

Страница 3: ...should be carefully checked to determine that it will operate properly and perform its intended function Check for alignment and binding of moving parts any broken parts or mounting fixtures and any other condition that may affect proper operation Any part that is damaged should be properly repaired or replaced by a qualified technician Do not use the tool if any switch does not turn On and Off pr...

Страница 4: ...cted to release any residual air in the chamber 4 Wear work gloves to protect your hands Warning The warnings cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be supplied by the operator Unp...

Страница 5: ...neuver the garden for trimming If the filter and oiler are not used connect the air hose directly to the 1 4 inch 18 NPT connector located at the Air Inlet 12 fitting Also a few drops of pneumatic tool oil must be added through the Air Inlet 12 before each use Note Use pipe thread seal or Teflon tape on all threaded connections Operation 1 Place the air supply sufficient length of air hose and Pne...

Страница 6: ... the Air Compressor Operator s Manual Manual Tool Lubrication 1 Disconnect the Pneumatic Shears from the air supply and turn it so the Air Inlet 12 fitting is facing upward 2 Hold the Trigger Lever 22 in and place one teaspoon of pneumatic tool oil into the air inlet use SAE 10 weight oil if air tool oil is not available Holding the Trigger Lever in helps circulate the oil in the air motor 3 Conne...

Страница 7: ...2 Trigger Lever 1 44 Blade Set 27 28 29 1 NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND T...

Страница 8: ...SKU 94593 For technical questions please call 1 800 444 3353 Page 8 Assembly Drawing ...

Отзывы: