NB7V33MMNGEVB
http://onsemi.com
6
NB7V33MMNGEVB TEST
Figure 7. Basic Lab Setup (Typical)
Power Supply
V
CC
V
EE
/DUTGND
DUT
Differential
Signal
Generator
Trigger
Out
Out
1. Connect appropriate power supplies to V
CC
, V
EE
/DUTGND, SMAGND, and ExPad (see Table 2).
2. Connect a signal generator to the input SMA connectors. Setup input signal according to the device data sheet.
3. Connect a test measurement device to the device’s output SMA connectors.
NOTE: The test measurement device must contain 50
W
termination.
V
EE
/
DUTGND
Power Supply
GND (0 V)
V
CC
Trigger
Test Measuring
Equipment
Channel 1
Channel 2
DUTGND/
V
EE
ExPad
SMAGND
Table 2. POWER SUPPLY LEVELS
Outputs
Power Supply
V
CC
V
EE
/DUTGND
SMAGND
ExPad
(typ)
CML
2.5 V
0 V
−
2.5 V
0 V
V
EE
/DUTGND
CML
1.8 V
0 V
−
1.8 V
0 V
V
EE
/DUTGND
Table 3. NB7xxxM, CML OUTPUTS “SPLIT” POWER
SUPPLY CONFIGURATION
Device Pin Power
Supply Convertor
“Spilt” Power Supply
V
CC
V
CC
= 0.0 V
SMAGND
V
TT
= 0 V
DUTGND
DUTGND =
−
2.5 V or
−
1.8 V
Figure 8. “Split” or Dual Power Supply Connections
+2.5 V
Dual Power Supplies
V
CC
DUTGND
SMAGND
+0.0 V
+2.5 V
−
+
−
+
Offset / “Split” Power Supply Configuration