NB7L14MMNEVB
http://onsemi.com
2
SETUP FOR TIME DOMAIN MEASUREMENTS
Table 1. BASIC EQUIPMENT
Description
Example Equipment
(Note 1)
Qty.
Power Supply with 2 outputs
HP6624A
1
Oscilloscope
TDS8000 with 80E01 Sampling Head (Note 2)
1
Differential Signal Generator
HP 8133A, Advantest D3186
1
Matched high speed cables with SMA connectors
Storm, Semflex
10
Power Supply cables with clips
4
1. Equipment used to generate example measurements within this document.
2. 50 GHz sample module used (for effective rise, fall and jitter performance measurement)
Setup
Step 1: Connect Power
1a: Three power levels must be provided to the board for
V
CC
, V
EE
, and GND via the surface mount clips.
Table 2. POWER SUPPLY CONNECTIONS
3.3 V Setup
2.5 V Setup
V
CC
= 0 V
V
CC
= 0 V
GND = 0 V
GND = 0 V
V
EE
=
−
3.3 V
V
EE
=
−
2.5 V
Step 2: Connect Inputs
For Differential Mode
2a: Connect the differential output of the generator to the
differential input of the device (CLK and CLK).
OUT
Channel 1
Channel 2
OUT
TRIGGER
Channel 3
Channel 4
TRIGGER
Amplitude = 400 mV
Offset =
−
200 mV
Signal Generator
CLK
CLK
V
CC
= 0 V
V
CC
V
EE
Q2
Q1
Q1
Q2
Digital Oscilloscope
V
EE
=
−
3.3 V (3.3 V op)
−
or
−
V
EE
=
−
2.5 V (2.5 V op)
GND = 0 V
GND
GND = 0 V
GND
Figure 2. NB7L14M Board Setup
−
Time Domain
(Differential Mode)
NOTE: All differential cable pairs
must be
matched.
Channel 8
Channel 7
Channel 6
Channel 5
Q3
Q0
Q0
Q3