ON Semiconductor Ezairo 7111 Pre Suite Скачать руководство пользователя страница 10

www.onsemi.com

10

ON Semiconductor Confidential

Ezairo® 7111 Pre Suite Getting Started Guide

3.4  Connecting the Programming Box

The programming box is connected to the Hybrid Demonstrator Board via the 6-pin DIN connector provided on the 

Hybrid Demonstrator Board. The programming box connection is either a similar 6-pin DIN connector, or in the case of 
the Promira, a 34-pin header adapter.

Next, connect the programming box to the PC using a USB cable. The fully connected system appears as shown in 

Figure 6.

Figure 6. Connected Ezairo 7111 Hybrid Demonstrator Board, Windows PC, and Programming Box

Once the system is connected, you can perform the initial communication from the PC to Ezairo 7111 (device 

connection).

4.  W

ORKING

 

WITH

 

THE

 S

OUND

D

ESIGNER

 SDK

4.1  Connect to Device

NOTE: The Ezairo Pre Suite firmware bundles are embedded within the Sound Designer Software. 

Options for selecting the appropriate firmware are provided upon initial connection to a device.

To establish a connection with the device, follow these steps:

1. Power on your device by plugging in the programming box and moving the Hybrid Demonstrator Board 

ON-OFF switch to the ON position (if not already done).

Содержание Ezairo 7111 Pre Suite

Страница 1: ...esigner Software the Ezairo 7111 Hybrid Demonstrator Board and a programming box that provides PC to device communications The following sections provide a brief overview of each component Figure 1 il...

Страница 2: ...provides a compression curve with four separate knee points expansion low level gain high level gain and output limiting Dynamic behavior covers a wide range through adjustable time constants Wideban...

Страница 3: ...logged in the buffer which assuming a log interval of 1 hour covers a total time period of over 4 weeks A separate long term data log keeps track of how much time has been spent in each program memory...

Страница 4: ...panel and a calibration and configuration utility This allows hearing aid manufacturers to create configure and test hearing aids more efficiently with less time spent on repetitive tasks The applicat...

Страница 5: ...ware see below for installation instructions An SDK reference guide is included with the SDK distribution package 2 4 Hybrid Demonstrator Board The Hybrid Demonstrator Board is designed to be used wit...

Страница 6: ...TIAL SETUP This section describes the initial setup for evaluating the Ezairo 7111 Pre Suite This includes downloading and installing the Sound Designer Software Windows application configuring the Ez...

Страница 7: ...directory and then follow the instructions below 3 2 Installation Instructions To install Sound Designer Software follow these steps 1 Double click sounddesigner_setup exe Follow the prompts for insta...

Страница 8: ...the SDK Readme html file located at the top level of the main ZIP file 3 3 Configuring the Hybrid Demonstrator Board Before connecting the Ezairo 7111 Hybrid Demonstrator Board to the programming box...

Страница 9: ...Properly Configured Ezairo 7111 Hybrid Demonstrator Board Table 6 Jumper Configurations for Ezairo 7111 Hybrid Demonstrator Board Jumper Switch Required Setting Description PSU SEL Short pins 1 2 Draw...

Страница 10: ...as shown in Figure 6 Figure 6 Connected Ezairo 7111 Hybrid Demonstrator Board Windows PC and Programming Box Once the system is connected you can perform the initial communication from the PC to Ezair...

Страница 11: ...eate one If you click Browse and select a pre existing directory for your workspace make sure it is empty To begin working with the Ezairo 7111 check Import Sample Workspace and select E7111 from the...

Страница 12: ...re 8 Opening the Control Panel and the Console Window 5 To configure device parameters click on the Control Panel icon circled in red in Figure 8 above and when prompted double click the Ezairo7111 pa...

Страница 13: ...re 9 Selecting the Parameter File 6 To connect to the device go to the Settings screen Select the correct Programmer and Port if applicable Next click Detect A successful detection populates the devic...

Страница 14: ...popup warning you that the device is configured with another library If you see this pop up click OK 9 Before communicating any parameter information Sound Designer Software checks the device to dete...

Страница 15: ...rmware 10 Once the connection succeeds the connection status symbol appears to the right of the file name as shown below in Figure 12 on page 16 You can hover over this symbol to view the programmer n...

Страница 16: ...d receivers or high impedance headphones It is available on pins 2 and 4 of the header pins labelled FILTEN0 The Demonstrator Board also provides a low pass filtered output that is more appropriate fo...

Страница 17: ...or This causes more indicator settings to appear 4 Select Tone Sequence as the Indicator Type 5 Select Output Referred as the Insertion Point 6 Select an Amplitude of 33 7 Slide the Tone 1 Duration sl...

Страница 18: ...algorithm parameters refer to the following resources Ezairo 7111 Firmware Bundle User s Guide Ezairo 7111 Pre Suite Getting Started Guide Ezairo Sound Designer Software Development Kit SDK Programme...

Страница 19: ...t be validated for each customer application by customer s technical experts ON Semiconductor does not convey any license under its patent rights nor the rights of others ON Semiconductor products are...