background image

CAT872EVB

http://onsemi.com

2

Table 1. CAT87xEVAL BOARD LIST OF COMPONENTS

Name

Manufacturer

Description

Part Number

Units

CAT871 or CAT872

ON Semiconductor

2 Input Reset Generator, ULLGA-6 Package

CAT871 or CAT872

1

C1

Taiyo Yuden

Ceramic Capacitor 0.1 

m

F/10 V, 10%, X5R, Size 0805

LMK105BJ104KV

1

MR1, MR2

HDT

Momentary Contact Switch SPST (on) - off

DTS67R

2

R1

Yageo

Resistor 10 k

W

, 1%, 1/8 W, Size 0805

RC0805FR-0710KL

1

R2

Yageo

Resistor 100 k

W

, 1%, 1/8 W, Size 0805

RC0805FR-07100KL

1

VDD, MR1, MR2,

GND, RESET

MPE Garry

Test points

BL1 x 36PF

6

Quick Test Procedure

1. Required Equipment

CAT87xEVAL Board

+5 V

DC

 Voltage Supply

Oscilloscope

2. Set-up

Verify that All the Power Supplies are Off

Connect the +5 V

DC

 Supply between the VDD

and GND Test Points of the CAT871EVAL
Board

Connect an Oscilloscope Probe to the RESET
Test Point

Connect an Oscilloscope Probe to the T_MR1
Test Point

Connect an Oscilloscope Probe to the T_MR2
Test Point

Turn on the +5 V

DC

 Voltage Supply

3. Operation Verification

Verify that the RESET Signal is Pulled High to
+5 V

DC

Press the MR1 Button, MR1 Signal Should Go
to GND on the Oscilloscope

Press the MR2 Button, MR2 Signal Should Go
to GND on the Oscilloscope

Press and Hold Down Buttons MR1 and MR2

Verify that the RESET Signal Low Pulse is
Generated after Three Seconds

Verify the Pulse width of the RESET Signal is
about 2.2 ms for CAT871 (70 ms for CAT872)

Release Button MR1. The RESET Pulse Should
not be Generated Anymore

Release Buttons MR1 and MR2

Turn off the +5 V

DC

 Voltage Supply

4. Start/Stop the Demonstration

At any Time the User Can Stop the
Demonstration by Releasing Both Push-buttons
and then Turning off the +5 V

DC

 Voltage

Supply