A5191HRTNGEVB
www.onsemi.com
16
Figure 21. Sample Slave Implementation
Master Implementation
An example of a possible master implementation is shown
in Figure 22. To use this schematic, the coupling capacitor
C4 on the A5191HRTNGEVB will need to be replaced by
a 0
W
resistor, or new biasing must be provided.
The current loop master has a sense resistor over which the
current flowing through the loop can be measured. The value
of this resistor varies depending on the sensitivity required
and range of the ADC.
A HART Master can have a sense
resistor ranging from 230
W
to 600
W
. Increasing the sense
resistor will result in higher amplitude HART signal
received, but will also reduce the voltage available on the
slave side. Furthermore, if you wish to sense the analog
transmitted signal, the MSB of your DAC may limit the
resistor size. If this limitation is too stringent, the sense
resistor can be split in two resistors, as shown in the figure,
effectively creating a resistor divider.
To transmit a HART signal, the TxA signal will need to be
amplified, as the A5191HRT transmit circuit can only drive
high impedance circuits (>30 k
W
). An additional
operational amplifier is required. Depending on the sense
resistor used, some gain or attenuation may be required to
get a 1 mA peak−to−peak HART output signal. This can be
accomplished by the resistors R
3
and R
4
. For a typical sense
resistor of 500
W
, a unity gain suffices and a unity gain
operational amplifier configuration can be used instead.
The amplifier however has a low impedance output,
which cannot be paralleled with the sense resistor, as this
would cause problems when the slave is transmitting. This
problem is solved by adding a series switch (such as
MC74VHC1G66DTT1G), controlled by the RTS signal.
For a normally open switch, the nRTS signal as applied to the
A5191 must be inverted first. To reduce power usage, the
operational amplifier can be disabled when the transmitter
is turned off. This is both done by inserting PNP transistor
Q
1
on the V
DD
connection of the amplifier
.
To couple the signal into the current loop, a single
capacitor was used. For other coupling techniques see
application note AND8346/D
.