On-Q IS-0369 REV. D Скачать руководство пользователя страница 3

 

 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 3 of 9

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ High Performance Keypad

 

IS-0369 REV. D

 

  ©Copyright 2009 by On-Q/Legrand All Rights Reserved. 

4)  Connections in the enclosure (see

 

Figure 3

): 

 
a)   The Category 5 cable that was run to each keypad location should be terminated with an RJ45 plug 

according to the T568A wiring standard and inserted into one of the zone output jacks of the associated 
lyriQ™ audio distribution module. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

b)   For the 16/4 speaker wire power cable that was run to each volume control location, strip 3/8” of 

insulation from each of the four conductors and insert the red and white wires into the red (plus ) portion 
of TB1. Insert the stripped black and green wires into the black (minus) portion of TB1  

 
NOTE: As noted before, Electricians may prefer to think of the black and red wires as plus and the 
green and white wires as minus. That wiring will also work, as long as it is also followed at each 
end of the cable. 

 
c)   To connect more than eight (8) Keypads to a 4 Source 8 Zone Module, cascade Single Source Modules. 

To cascade a Single Source Module, simply run a Cat 5e jumper from any Zone port RJ45 jack on the 
front panel of the Multi-source Module to the “Source In” RJ45 jack on the front panel of a Single Source 
Module (see 

Figure 4

). 

 
 
 
 
 
 
 
 

Figure 3 

Содержание IS-0369 REV. D

Страница 1: ...AU7394 xx It also has push buttons for VOLUME UP DOWN with five associated green Volume Bar Graph LEDs SOURCE with four green Source Selection LEDs and MUTE with one red status LED There is also an IR target window and tri colored status LED The visual cue from the front panel that this is a High Performance Volume Control are the parenthesis surrounding the music note in the lower right hand corn...

Страница 2: ...g outlet box or mud ring at each Volume Control location B Trim out steps 1 Connect the volume control by terminating the pre wired Category 5 cable from the enclosure with an RJ45 plug following the T568A wiring standard and insert this plug into jack J1 see Figure 2 2 For the power connection TB1 strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the...

Страница 3: ...n to each volume control location strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the red plus portion of TB1 Insert the stripped black and green wires into the black minus portion of TB1 NOTE As noted before Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus That wiring will also work as long ...

Страница 4: ...rformance Keypad IS 0369 REV D Copyright 2009 by On Q Legrand All Rights Reserved 5 Keypad Mounting check all connections and test the system s operation before installing the volume controls into the wall Use the included screws to install the volume control and wall plate into the single gang box NOTE A 20 in or greater single gang box is recommended Figure 4 ...

Страница 5: ...OWN button to adjust back light level Press SOURCE or MUTE button to exit or wait for 10 second time out see Figure 5 NOTE When any Keypad button is tapped back light level goes to full bright and returns to the adjusted level when activity ceases For Remote operation the back light goes to full bright when an IR command is received and returns to the adjusted level when activity ceases F Temporar...

Страница 6: ...e Source Control mode and press the SOURCE button it will cause everyone to go to 4 and then 1 and then 2 and finally to 3 while double tapping it will cause every active keypad to go directly to Source 3 NOTE The Whole House Source Control mode will be exited when the user fails to press a key within 5 seconds or by pressing and holding the MUTE and SOURCE buttons simultaneously as before 5 Impor...

Страница 7: ... to be controlled from other keypads on the system that have engaged Whole House Mode Whole House Disable src 1 vol 2 turns off the ability of a keypad to be controlled by other keypads that have engaged Whole House Mode Will not respond to audio interrupt Will still be able to implement a Whole House command from keypad Keypads connected to systems with the Integration Module will not be controll...

Страница 8: ... radiated interference Grouping Studio Keypads Only Default src 1 3 vol 1 Keypad is not grouped Keypads not on a system with the Integration Module should be set to the default setting Keypads with Integration Module on system will provide information to the Integration Module to be displayed for the end user Member of a Group src 1 3 vol 2 Keypad will not provide information to the Integration Mo...

Страница 9: ...1 IR Carrier Frequency at 56kHz src 1 4 vol 3 Default is used for normal operation and environments The default will be effective for the vast majority of source devices Carrier frequency can be changed if end user s source device does not respond to multi burst IR Carrier Frequency Adjustments are chosen based on end user s remotes Most devices are 40kHz Cable and satellite boxes are often 56kHz ...