1.  Introduction 

 
The part no. 364806 HMS EZ-Scene ALC Lighting Interface 
enables any On-Q HMS Controller or HAI OMNI controller to 
control On-Q’s Advanced Lighting Controls.  Additionally, the 
expansion module provides local lighting scene programming 
capability.  EZ-Scene programming allows ALC 4-Button Scene 
Switches and RF Remote Controls to learn the lighting level 
settings of ALC Dimmers, Relay Switches and Non-Dimming 
controls independent of the HMS Controller. 
 
The part no. 364806-01 1-Branch HMS EZ-Scene ALC 
Lighting Interface provides control of up to 31 ALC controls.  
The part no. 364806-02 4-Branch HMS EZ-Scene ALC 
Lighting Interface provides control of up to 124 ALC controls. 
Both expansion module part nos. support a total of 64 EZ-Scene 
local lighting scene programs. 
 
The On-Q HMS Model 800 controller provides direct control 
of  up  to  16  ALC  controls  on  branch  no.  1.   The  HMS  Model 
950 controller provides direct control of 62 ALC controls on 
branch nos. 1 and 2. The HMS Model 1100 controller provides 
direct control of up to 248 ALC switches using up to two part 
no. 364806-02 EZ-Scene ALC Lighting Interface modules. 

2. Installation 

 

Note: If other expansion modules are connected to the HMS 
controller, the EZ-Scene ALC Lighting Interface must be 
installed first, that is directly above the HMS controller. 

 
1. Remove 4 6/32 x 1/4 Phillips screws indicated as "A" in 
Figure 2.  Replace the screws with the 4 supplied 6/32 x 1/2 
male/female Hex Standoffs.  Retain screws for future step. 
 
2. Connect supplied cable to 20 pin connector on controller 
indicated as "B" in Figure 2. 
 
3. Align the interface PCB with the hex standoffs and secure 
with the 4 screws removed in step 1. 
 
4. Connect opposite end of supplied cable to the 20 pin 
connector on the interface PCB indicated as "C" in Figure 2. 
 
5. Ensure that the address jumper indicated as "D" in Figure 2, 
is set to a unique address. Factory setting is address no. 2. 
 
Note:  This example is for the HMS 800.  For Models 950 and 
1100 mounting is to the right side of the controller, the same 
procedure should be followed.  
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 