LIBRETTO ISTRUZIONI - INSTRUCTION MANUAL
NO
RX
FIGURE 3
6
FIGURE 1
FIGURE 2
2- TECHNICAL DATA:
before installing the product, check that the area of installation is compatible with the temper-
ature limits.
Description
Value
Power supply
12V/24V selectable with JPA
Power supply range
12-32 Vdc - 12-30 Vac
Relay contact capacity
1A - 30Vdc/Vac
Maximum capacity
25m (reduced in relation to environmental conditions)
Max consumption TX
30mA
Max consumption RX
40mA
Response time
40ms (normal) – 300ms (snow filter function)
Operating temperature
between -20 and +70°C
Degree of protection
IP 54 (EN60529)
Dimensions L x H x W
113mm x 40mm x 36mm
3- INSTALLATION:
set the dipswitches and jumpers before powering
the photocells; always turn off the power before making adjustments and do
not turn it on again until afterwards.
To remove the cover before installation, use a screwdriver to gently lever it
up at the point of one of the lower fixing holes behind the base of the photo-
cell, as shown in figure 1.
It is advisable to not install the receiver directly facing the rising sun (see
figure 2); the photocells receiver is sold with a filter S on the lens. In case you
want to improve the photocells range, remove the filter S (pic. 3-1).
Make the connections using cables measuring between 0.25 and 0.50 mm
2
.
Install the photocells on flat surfaces in the position required by the regula-
tions in force, making sure to align them one in front of another at the same
height. To adjust the angle, simply loosen the two screws C and turn the
support board I (see figure 3).
In order to remove the cover after the photocell is installed, simply undo
screw A (see figure 4) and pull the cover B upwards moving it diagonally.
This symbol draws attention to information to be read with care
This symbol draws attention to information concerning safety
This symbol draws attention to information concerning the wiring
1- WARNINGS:
the FT180 wall-mounted 180° rotating photocells are suitable for installation on the automation devices
of gates or doors. They can be used as a Type D device in accordance with standard EN12453 if connected to a control unit
with safety device control feature, or if checked every six months as part of the system maintenance schedule. The coded
synchronism allows all the transmitters to be mounted on the same side (up to a maximum of four). This avoids the risk of
reflection associated with the cross-wise pattern of conventional photocells.
Key of the symbols in this manual:
S
FIGURA 3-1
LIBRETTO ISTRUZIONI - INSTRUCTION MANUAL