Error messages in the display of the hand switch (optional) 

Display 

Description 

Remedy 

 

Short-circuit motor 1 

Pull the mains plug. Correct the external short-circuit, 
check the cables to the motors for damage or connect 
the correct motor to the relevant socket. Start the 
controller again. If required, carry out a reference 
movement. 

 

Short-circuit motor 2 

 

Cable of motor 1 was pulled 

Check the plug/cable connection to the motors and 
carry out a reference movement. 

 

Cable of motor 2 was pulled 

 

No pulses measurable 

Pull the mains plug. Correct the external short-circuit, 
check the cables to the motors for damage or connect 
the correct motor to the relevant socket. Start the 
controller again. If required, carry out a reference 
movement. 

 

System protection/ System pause 
The controller monitors the power-on 
duration (time-controlled) and its 
maximum temperature. One of the two 
values was exceeded. 

Wait till the controller has cooled and the display 



 

goes off. There is now clearance for movement for 20s. 
Only after 18 minutes will the table move the full 2 
minutes. ATTENTION! The power-on duration is 
calculated even if there is no mains voltage applied. 

 

Collision detected 

 

 

Overcurrent at motor 1 

Collision?  
If required, rectify; max. load exceeded; remove the 
load from the table. 
Motor positions too much at variance; if required, 
reduce the load on the table. Carry out a reference 
movement. 

 

Overcurrent at motor 2 

 

The motors have lost sync. 

Motor positions too much at variance; if required, 
reduce the load on the table. Carry out a reference 
movement. 

 

The controllers are out of sync 
(cascading). 

Check whether the cascading cable between the 
controllers is correctly inserted and that there is a mains 
cable in both controllers. 
 Carry out a reference movement. 

 

Sensor module error 

Further movements are possible, but without anti-
collision protection. Inspect the sensor module. 

 

Contradictory operations on two different 
controller devices. 

Stop operation at all the available controller devices. 

 

The “Up” key on the hand switch is stuck.  Replace hand switch. 

 

The “Down” key on the hand switch is 
stuck. 

Replace hand switch. 

 

Voltage too small 

Pull the mains plug. Contact Customer Service. Mains 
or power supply fluctuations? 
 
 
 

 

Voltage too high 

 

Discrepancy in the parameters  

The parameters in one controller do not match the 
number of legs or the parameters are not the same in 
the two controllers.  
Contact Customer Service and have the parameter set 
of the table checked. 

 

Reference movement required. 

Carry out a reference movement. 

 

The table moves 

  

Table 2: Error descriptions (Motor = drive in the mounting leg or in the side frame) 
 

 

Содержание FREE.STAND 9051

Страница 1: ...sanleitung_C1_Rev2_EN_UK 08 08 2018 TS MB Installation and operating instructions Electrically height adjustable sit stand work desks System FREE STAND 9051 with motor controller STAND CONTROL C1 E co...

Страница 2: ...he controller and hand switch 12 5 Commissioning 13 5 1 Connections to the STAND CONTROL C1 motor controller 13 5 2 Procedure during commissioning 14 5 2 1 Connect the drives 14 5 2 2 Connect the hand...

Страница 3: ...sanleitung_C1_Rev2_EN_UK Stand 08 08 2018 TS MB 3 10 Error messages in the display of the hand switch optional 22 11 Click codes of the controller 24 12 Technical Data 25 13 Tests and certificates 26...

Страница 4: ...1 1 Use as intended This sit stand desk may be used solely as an office desk in the professional sector Changes to the desk base are prohibited This sit stand desk must be assembled put into operation...

Страница 5: ...ote Pull the power cord before going to the next step 1 4 Safety Instructions These operating instructions contain safety instructions which inform you about potential hazards and thus facilitate the...

Страница 6: ...hes or any other accessories on the motor controller on or off Attention Use solely original FREE STAND accessories from Oelschl ger Metalltechnik GmbH Use of components and parts from third parties i...

Страница 7: ...e desk in explosive environments 1 4 3 Before initial operation Make sure the desk is assembled in accordance with these instructions Make sure that the side panels are perpendicular to the table top...

Страница 8: ...rnings in the operating instructions and or safety instructions on your product Warning Make sure that no unauthorised persons small children persons under the influence of medication etc handle your...

Страница 9: ...changes are permitted to be made on the desk base otherwise the warranty expires Please refer to our General Terms and Conditions for additional information 3 Maintenance Cleaning Regularly remove du...

Страница 10: ...ake sure the product is acclimatised for the temperature and relative humidity values stated in the technical data 4 1 Installing the crossbeams and table top supports or the upper frame Now fit the t...

Страница 11: ...g The max tightening torque is 10 Nm The max screw in depth of the screws M10 into the drive column is 12 mm With asymmetric skids C form keep in mind that one left and one right side frame might be r...

Страница 12: ...the motor controller and click the brackets into place with moderate pressure on both the components on the controller Now fit the hand switch on the table top There are holes of 5 2 mm provided on th...

Страница 13: ...technical apprenticeship and are familiar with these operating instructions Attention Before assembly and commissioning of the FREE STAND sit stand desk make sure the product is acclimatised for the t...

Страница 14: ...re For especially large desks if necessary use an extension cable for the connection cable of the drives Connect the drives of the side element and the controller using the motor cable The plug connec...

Страница 15: ...ll cables to the desk base or the desktop so they cannot get damaged during operation 5 2 4 Installing optional accessories There is a large number of optional accessories available for the FREE STAND...

Страница 16: ...he table moves into the minimal position Releasing the button too early can result in a malfunction at the table If that should happen you must repeat the procedure Attention The top limit stop of the...

Страница 17: ...Previously stored positions can be taken up with the position keys 1 4 Note All hand switches are plug play capable and can be operated in parallel 6 3 1 How to save a position Move the table to the...

Страница 18: ...econds 2 Confirm menu option by once again pressing the Logo key 3 Now select with the a key Up arrow inches or b key Down arrow cm 4 Confirm the selection by once again pressing the Logo key To quit...

Страница 19: ...position by a mobile file cabinet container stop 6 3 7 1 Setting menu F4 To set a shelf or container stop follow the procedure below 1 Use the arrow keys to move to the desired position 2 Press the L...

Страница 20: ...zone 7 Cascading 2 Controllers 2 drives maximum can be connected to one controller To increase this number to 4 two controllers can be cascaded 1 To do so 2 controllers must be configured with a param...

Страница 21: ...troller will independently reactivate after approx 3 minutes ATTENTION The max travel time of 2 minutes is only available after an idle time of at least 18 minutes Drive defective Please contact Custo...

Страница 22: ...Overcurrent at motor 1 Collision If required rectify max load exceeded remove the load from the table Motor positions too much at variance if required reduce the load on the table Carry out a referenc...

Страница 23: ...the mains cable is pulled a manual reset might be necessary If the error cannot be repaired as described above pull the mains plug wait for several minutes and try to reinitialise the desk If the err...

Страница 24: ...l operation The system works without any problem 1x Up key pressed Reset Initialisation movement required 7x During the movement the connection to a drive is lost Error Table cannot be moved any more...

Страница 25: ...eration Ambient conditions during transport and storage weight approx 500g Protection class II IP Class IP 20 Max operating time 2 Min ON 18 Min OFF Individual drive installation column or side panel...

Страница 26: ...sure EN 60335 1 2012 Household and similar electrical appliances Internal and similar uses Safety related parts of controllers EN ISO 13849 1 2015 Safety of machinery Safety related parts of control s...

Страница 27: ...2018 TS MB 27 13 Address Oelschl ger Metalltechnik GmbH Hertzstra e 1 3 27318 Hoya Germany Tel 49 0 4251 816 0 E mail info oelschlaeger de Internet www oelschlaeger de Company Headquarters Hoya Distri...