OPERATION

 

 

INFORMATION

INITIALIZATION/RESET  

The desk may need to be initialized/reset after any of the following:

 

- After assembly 
- After disconnection from the power supply  
- After any impact on the table top.

To initialize/reset, you will need to move the table to the lowest position by holding the DOWN

 button of 

the handswitch until all columns reach the lowest position. Then press the DOWN button again and hold it 
pressed for five seconds or until a slight movement of the table drops down to the machine zero point and 
back up to the operation zero point. Once the table stops moving, release the DOWN button. If the button is 
released too early, this leads to a malfunction of the table and you must repeat the reset process.

The upper height position is programmed into the control box. For this reason, only use the control box that 
has been provided with the specific table frame. 

Under no circumstance should a control box from one 

table be moved to another.

NORMAL HANDSWITCH OPERATION  

(for all handswitch types)

 

 

By pressing the UP or DOWN buttons, the table will move up or down to the desired position. Once the desired 
position is reached, let go of the UP or DOWN button. The table will stop once it reaches the lower or upper 

height position. 

PROGRAMMABLE HANDSWITCH OPERATION  

(optional)

 

 

This programmable handswitch is  

equipped with a display for showing 

 

the current table height in centimeters 
or inches.

The handswitch also will display an error code if an error is detected by the control box. When an error 

 

is detected, the display will show an error code “EXX,” instead of the current table height. To resolve the 

 

error, see the Troubleshooting Section (p. 12-13 of this guide).

The programmable handswitch also has the ability to save up to four different height positions.

OPERATION INFORMATION

1

s

2

3

4

Содержание 99848

Страница 1: ...USER GUIDE OV1018 Part No 99848 OV1018 HEIGHT ADJUSTABLE TABLE...

Страница 2: ...sy assembly and hundreds of color combinations with a well designed and contemporary product This line is both useful and attractive with coordinating fixed height T Leg C Leg X Base and Flip Top opti...

Страница 3: ...he Height Unit 11 Adjust Height Display 11 Save Memory Position 11 Recall Memory Position 11 Troubleshooting 12 13 Unit Errors 12 Handswitch Errors 13 Technical Data 14 Standards Certifications 15 TAB...

Страница 4: ...8 PARTS DIAGRAM PARTS Qty Package 1 Column 2 2 Top Support 2 3 Foot 2 4 Adjustable L Rail 2 5 Control Box 1 6 Handswitch 1 7 Power Cord 1 8 M10x1 5 50mm Screw 4 9 M6x1 0 12mm Screw 10 10 Glide 4 PARTS...

Страница 5: ...HEIGHT Body parts and property can be caught between the moving work surface and an immobile obstacle such as shelves furniture window sills or walls Keep at least one inch of clearance around desk a...

Страница 6: ...le needs service contact customer service Never operate this furnishing if it has a damaged cord or plug if it is not working properly or if it has been dropped or damaged Return the furnishing to a s...

Страница 7: ...tightening torque for these screws is 9 9Nm 7 3 ft lbs 1 1 Assemble the column to the L rail 2 Assemble the top support to the column 3 Assemble the foot to the column 4 Fasten the table frame onto t...

Страница 8: ...ening torque for these screws is 9 9Nm 7 3 ft lbs 2 ASSEMBLE THE FOOT TO THE COLUMN Assemble using the M10x1 5 50mm length screws 2 per column The maximum tightening torque for these screws is 48Nm 35...

Страница 9: ...on FASTEN THE CONTROL BOX AND HANDSWITCH TO THE TABLE TOP Make sure the control box and handswitch are fastened in a location where all the cables will connect without being in tension Be sure to use...

Страница 10: ...For this reason only use the control box that has been provided with the specific table frame Under no circumstance should a control box from one table be moved to another NORMAL HANDSWITCH OPERATION...

Страница 11: ...or 5 seconds until the display starts to flash 3 Measure the table height and enter the measured value depending on the setting in centimeters or inches with the UP or DOWN button Confirm the entry by...

Страница 12: ...e the weight or load on the desktop Replace the handset Max time limit is exceeded Control is activated automatically after approx 9 minutes Defective drive Contact customer service Defective control...

Страница 13: ...ercurrent If the problem still exists please contact customer service If necessary reduce the load on the table Reset the table see page 10 Option ISP function Remove source M2 Overcurrent M3 Overcurr...

Страница 14: ...put current 5 A Standby power consumption primarily 0 3 W Operating temperature 0 35 C Protection class IP 20 Maximum duty cycle 5 1 min on 18 min off Maximum power output 216VA 24V TWO COLUMN FRAME W...

Страница 15: ...ANTY INFORMATION WARRANTY Meets 2014 BIFMA standards CUSTOMER SERVICE End of life cycle Once product is disassembled all steel components can be recycled at your local metal collector For products wit...