31
CHAPTER
9
TROUBLESHOOTING
9.1
TROUBLESHOOTING
The most common problems that could occur while using the slicing machine are
listed below, along with the most probable causes and solutions for dealing with
them. If the problem continues, contact the authorised service provider.
Control panel - display
3
(Fig. 8) - the following message appears:
Emergency microswitch contact open.
Error reading the carriage forward magnetic
microswitch.
Error reading the carriage back magnetic
microswitch.
For the errors described above, contact your authorised service provider.
PROBLEM
PROBABLE CAUSE
SOLUTION
The motor does not
start when the start
blade button is pressed.
No power to the
machine.
Check that the machine plug
is inserted correctly.
No power to the
mains.
Check that power reaches
the electrical system outlet.
Faulty electrical circuit. Contact the authorised
service provider.
Under stress, the blade
slows down or stops.
Cutting of products
which are not allowed
(frozen products or
products with bones).
Thaw the product or take
the bone out of the product
to be cut.
Machine set for 400 V.
three phase voltage
but connected to 230
V three phase power.
Unplug the machine from the
mains and contact the
authorised service provider.
The motor starts up
but the machine is very
noisy or the motor
overheats or there is a
bad smell.
Transmission or motor
problems.
Unplug the machine from the
mains and contact the
authorised service provider
Содержание KEA 300 TGI
Страница 1: ...1 Use and maintenance manual AUTOMATIC SLICING MACHINE Edition January 2016 EN...
Страница 4: ...4 CHAPTER 9 TROUBLESHOOTING 31 9 1 TROUBLESHOOTING 31...
Страница 10: ...10 1 3 3 COMPOSITION OF THE MACHINE Normal tray Tray with adjustable rods...
Страница 12: ...12 CHAPTER 2 TECHNICAL DATA 2 1 DIMENSIONS WEIGHT SPECIFICATIONS Figure 2 Overall dimensions...
Страница 19: ...19 4 3 2 WIRING DIAGRAM OF THE SINGLE PHASE SYSTEM Figure 7 230 V single phase wiring diagram with SCHUKO plug...
Страница 33: ...33...
Страница 34: ...34...
Страница 35: ...35...