Connecting Two or More Amplifier Units
Use a Calculating Unit to connect Amplifier Units when performing calculations between
Amplifier Units and to prevent mutual interference between Sensor Heads.
The number of Amplifier Units that can be connected differs depending on the functions to
be used.
• Supply power to all connected Amplifier Units at the same time.
• When connecting two or more Amplifier Units, the response times (maximum values) are as
follows:
<Response time if mutual interference prevention is set to ON>
Function
Number of Connectable Amplifier Units
See:
Calculation
Up to two units (Up to five units can be connected.
However, calculations are done between pairs of two.)
(A-B)
calculation:
Page 47
Thickness
calculation:
Page 57
Mutual interference
prevention
Up to five units
Mutual Interference
Prevention
Two-Sensor
Operation
Total Response Time
OFF
OFF
Response time setting for each CH
(A – B), THICK
(Total response time setting for each CH) +
(4 ms × number of connected units)
ON
OFF
(Response time per unit (T) in the table below) ×
number of connected units
(A – B), THICK
CH1 Response Time Setting
Response Time per Unit (T)
60 µs
3 ms
120 µs
3 ms
240 µs
3 ms
500 µs
4 ms
1 ms
8 ms
2 ms
16 ms
4 ms
32 ms
8 ms
64 ms
12 ms
72 ms
20 ms
80 ms
36 ms
100 ms
66 ms
160 ms
128 ms
280 ms
250 ms
520 ms
500 ms
1 s
CH1
CH2
CH3
CH4
CH5
(CH2-CH1)
(CH3-CH1)
(CH4-CH1)
(CH5-CH1)
For (A-B) calculations
A: CH2 or later
B: CH1
Important