Mutual Interference Prevention
Mutual interference prevention:
This refers to the function for preventing the influence of Sensor Heads when
mounted close to each other. (This function can be used for up to five Amplifier Units
connected by using Calculating Units (ZX2-CAL).)
Procedure for setting up mutual interference prevention
1
Set to the MENU mode
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button of the
CH1 Amplifier Unit for three
seconds to switch to the MENU
mode.
Press the button to display
.
* This step is not required if
detail menu display is
already set to ON in the
MENU mode.
Press the button to set the
display to
to set display of
the detail menu.
Press the
button to apply
the setting.
Mutual interference
prevention setting
2
Return to RUN mode
3
Set to the MENU mode
1
Setting completed
CH1
CH2
CH3
CH4
CH5
Calculating Unit
Amplifier Unit
Set on CH1 Amplifier Unit
Hold down for
3 seconds
Lit
Press to display
.
Press to display.
Setting channel: CH1