Auto-scaling
Select either millimeters or a percentage for the display on the main dis-
play and whether the incident level or intercepted amount is displayed.
The current incident level (intercepted amount) is automatically scaled,
displayed, and output with respect to the reference incident level.
The default display setting is 100-L.
Note 1.
When 100-L or 100-d is selected, the incident level is displayed as a
percentage.
2.
The above table shows values when the monitor focus function is not
used.
3.
When scaling for values other than 5, 10, or 30 mm, use the 2-point
scaling function.
4.
Set the monitor focus after the auto-scale setting.
Refer
to
4-5-13 Auto-scale Settings
for the setting proce-
dure.
Note:
When the auto-scale function is set, all settings are automatically reset to
their default values.
5-L
5-d
10-L
10-d
30-L
30-d
100-L
100-d
Display
5.000
0.000
10.000
0.000
30.000
0.000
100.00
0.00
Linear
output
+4 V
20 mA
−
4 V
4 mA
+4 V
20 mA
−
4 V
4 mA
+4 V
20 mA
−
4 V
4 mA
+4 V
20 mA
−
4 V
4 mA
Display
2.500
2.500
5.000
5.000
15.000 15.000 50.000 50.000
Linear
output
0 V
12 mA
0 V
12 mA
0 V
12 mA
0 V
12 mA
0 V
12 mA
0 V
12 mA
0 V
12 mA
0 V
12 mA
Display
0.000
5.000
0.000
10.000
0.000
30.000
0.00
100.00
Linear
output
−
4 V
4 mA
+4 V
20 mA
−
4 V
4 mA
+4 V
20 mA
−
4 V
4 mA
+4 V
20 mA
−
4 V
4 mA
+4 V
20 mA
For no interception
Emitter
Receiver
For half interception
Emitter
Sensing object
Receiver
For full interception
Emitter
Sensing object
Receiver
Содержание ZX Series
Страница 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Страница 2: ......
Страница 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Страница 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Страница 160: ...FUN Function Mode Section 4 5 140 Memo ...
Страница 166: ...Setting Problems Section 5 2 146 Memo ...
Страница 185: ...Dimensions Section 6 2 165 6 2 4 Calculating Unit n ZX CAL Connectors Connection indicators Unit mm ...
Страница 186: ...Dimensions Section 6 2 166 Memo ...
Страница 187: ......
Страница 188: ...Z157 E1 01B ...