Setting the Output Conditions
96
ZW User's Manual
Setting the Frequency Filter
Set a filter to ignore or detect the changes in a specific frequency in the measured data.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Task Settings] icon (
)
Task Settings window : [Filter]
• Set the cut-off frequency to a value smaller than one-half of the sampling frequency. Otherwise, the frequency filter
will not function properly. If a value outside of the appropriate range is set, the frequency filter will be applied with
the values included in the range.
• If the cut-off frequency values (upper/lower limits) are too close, the frequency bandwidth to be detected cannot be
properly detected.
• The sampling frequency is the inverse of the measuring cycle.
• The measuring cycle can be viewed in the "System Information" menu on the Sensor Controller.
Item
Setting item
Setting value
Description
Frequency filter
Frequency filter
OFF (default value)
Frequency filter is not used.
Lowpass filter
Ignores frequency components larger than the specified
cut-off frequency. (Only gradual changes are captured.)
Highpass filter
Detects frequency components smaller than the specified
cut-off frequency. (Sudden changes are captured.)
Bandpass filter
Detects the frequency components between the cut-off
frequency (lower limit) and the cut-off frequency (upper
limit).
Cutoff frequency
0.001 (default value) to
999.999 [Hz]
Set this item when a low pass filter or a high pass filter is
selected.
Cutoff frequency (Upper
limit)
0.001 (default value) to
999.999 [Hz]
Set this item when a band pass filter is selected.
Cutoff frequency (Lower
limit)
1
Select the frequency filter type from
[Frequency filter].
2
Set the cutoff frequency from [Cutoff
frequency]. When a band pass filter is
selected, set [Cutoff frequency (upper limit)]
and [Cutoff frequency (lower limit)].
The frequency filter can also be set by the operating keys on the Sensor Controller.
Setting the Frequency Filter p.312
Note
Important
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......