Setting the Output Conditions
310
ZW User's Manual
9-8 Setting the Output Conditions
Setting the Filter
Setting the Median Filter
Setting the Median Filter p.94
As an example, here is an explanation of the procedure for selecting the "MID" median filter setting.
Operating procedure
Steps
Key operation
Display
Description
1
Press and hold the
key for two seconds to enter the FUN
mode.
2
Press the
/
key to select MEAS, then press the
key.
3
Press the
/
keys to select "TASK1" and press the
key.
4
Press the
/
keys to select "FILTER" and press the
key.
5
Select "MEDIAN" as the filter type.
Press the
/
keys to select "MEDIAN" and press the
key.
6
Select the filter mode from the following:
OFF / LOW / MID / HIGH
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "MID" and press the
key.
7
Press the
key for two seconds to enter the RUN mode.
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......