4
5
No dead zones even without using a staggered arrangement.
By arranging discharge electrodes on both ends, the Ionizer can handle an area wider than the length of the Ionizer itself. This eliminates
dead zones even when linking Ionizers, and achieves uniform ionization.
Air supply
port
Positive charge
Positive charge
The Ionization range is wider than the length
of the Ionizer itself.
Supplying air with no pressure loss
The air supply ports on previous models were only on both ends, so the airflow was weak in the center of long
Ionizers. By connecting ZJ-BAS Ionizers together, air is supplied from the center part as well, thus achieving a
uniform airflow and eliminating uneven ion discharge at medium and long distances.
Technology 1
Linked Ionizers cover a wide area without causing uneven ionization.
Linking
up to
7
Units
*
For example, when both sides of a workpiece are charged, a long Ionizer will adjust the amount of ions
according to the entire Ionizer length, so an area that is not charged may take on a reverse charge. By using
linked ZJ-BAS Ionizers, each Ionizer senses the charge condition. Because only the Ionizers on both ends then
control their ion amounts in response to the charges, reverse charging does not occur.
Uniform
Airflow
Uniform
Ion Balance
A New Proposal for Effective and Efficient Ionization
Ion Sensing and variable-AC system prevents ion recombination
Because the ZJ-BAS Ionizer uses a method in which the linked Ionizers operate using the same power supply, the positive and negative ion
generation timing between the Ionizers is synchronized. Also, the sensing and variable-AC system control the amount of ions while
synchronizing the Ionizers. This reduces ion recombination between the linked Ionizers, and achieves uniform ionization.
Technology 2
lIon Sensing and Variable-AC System
lAC System
The amount of ions is adjusted even when a charge is detected,
so synchronization with matching polarity is maintained.
*
For information on requirements for linking Ionizers,
contact your OMRON sales representative.
Ionizer A
Ionizer B
If the synchronization of the timing is lost,
the polarity is reversed.
Ion recombination
Long Ionizers are required to meet the needs of increasingly large liquid crystal glass panels.
Ionizers as long as two meters are not only difficult to transport and install,
but also pose difficulties in achieving uniform ionization.
The highly thorough ZJ-BAS Ionizer solves this problem by connecting Ionizers together.
Uniform Ionization
Airflow in the center
part is weak.
lPrevious Model
Two Forms of Uniform Ionization Achieved by Linking Function
Uniform Ionization
Technologies that Support Uniform Ionization