Enclosed Switches
ZE/ZV/XE/XV
F-121
Lim
it
Switch
es
■
Ratings
Note: 1.
The above figures are for standard currents.
2.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
■
Characteristics
Note: 1.
The above figures are initial values.
2.
IP65 for
@
E-N models and IP60 for
@
E-Q models.
3.
The values are calculated at an operating temperature of 5
°
C to 35
°
C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
4.
At the operation limit positions.
5.
Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
6.
Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
Contact
Contact
Rated voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
ZE-
@
ZV-
@
ZV2-
@
125 VAC
15 A
3 A
1.5 A
15 A
5 A
2.5 A
250 VAC
15 A
2.5 A
1.25 A
15 A
3 A
1.5 A
480 VAC
10 A
1.5 A
0.75 A
6 A
1.5 A
0.75 A
125 VDC
0.5 A
0.5 A
0.05 A
0.05 A
250 VDC
0.25 A
0.25 A
0.03 A
0.03 A
XE-
@
XV-
@
XV2-
@
8 VDC
15 A
3 A
3 A
15 A
15 A
10 A
10 A
14 VDC
15 A
3 A
3 A
15 A
10 A
10 A
10 A
30 VDC
15 A
3 A
3 A
10 A
10 A
10 A
6 A
125 VDC
10 A
3 A
1.5 A
7.5 A
6 A
6 A
4 A
250 VDC
3 A
1.5 A
0.75 A
2 A
1.5 A
2 A
1 A
Inrush current
NC
30 A max.
NO
15 A max.
Degree of protection
IP65 (see note 2)
Durability (see note 3)
Mechanical:
Z
@
: 10,000,000 operations min.
X
@
: 1,000,000 operations min.
Electrical:
Z
@
: 500,000 operations min., for 15 A, 250 VAC resistive load
X
@
: 100,000 operations min., for 10 A, 125 VDC resistive load
Operating speed
Plunger type: 0.01 mm to 0.5 m/s
Lever type:
0.02 mm to 0.5 m/s
Operating frequency
Mechanical: 120 operations/min
Electrical:
20 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Contact resistance
15 m
Ω
max. (initial value)
Terminal temperature rise
50
°
max.
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part (1,500 VAC for Z
@
models and X
@
models)
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)
Shock resistance (see note 4)
Destruction: 1,000 m/s
2
min.
Malfunction: 100 m/s
2
min. (see note 5), 50 m/s
2
min. (see note 6)
Ambient temperature (see note 1)
Operating: –10
°
C to 80
°
C (with no icing)
Ambient humidity
Operating: General-purpose type: 85% max.
Sealed type:
95% max.
Weight
Approx. 260 to 280 g