For the Safety Precautions for All Limit Switches, refer to the OMRON website.

Meanings of Warning Signal Text

• Be sure to ground. Otherwise electric shock may result.
• Do not touch charged switch terminals while the switch has carry 

current, Otherwise electric shock may result.

• Do not disassemble the limit switch or touch inside of it under 

supplying power, Otherwise electric shock may result.

• Do not disassemble or touch the inside while the power is turned 

on. Otherwise electric shock may result.

• Do not touch the wire or rod type actuator in order to prevent injury. 

Doing so may result in injury.

• Connect a fuse which has 1.5 to 2 times higher breaking current 

than the switch rated current to the switch in series in order to 
prevent the switch from short-circuit damage.

• On the occasion when using the switch with EN/IEC/GB ratings, 

use a 10 A fuse that complies IEC60269, either type gG.

• The durability of switch is depends on the operating condition Be 

sure to check the condition with actual using condition before 
using, and use with the number of times of operating without a 
performance problem.

• Otherwise, there is the possibility of spoiling the normal operation. 

Do not drop the switch.

• Do not connect a Single Limit Switch to two power supplies that are 

different in polarity or type. Risk of interference.

• Be sure to keep the load current less than the rated value. 

Otherwise, there is the possibility that the switch may be damage 
and/or burnout.

• Do not use the Switch by itself in atmospheres containing 

flammable or explosive gases. Arcs and heating resulting from 
switching may cause fire or explosion.

• Be sure to prevent the foreign materials such like a scrapped cable 

intrusion in to the switch when wiring. Otherwise, there is the 
possibility of spoiling the normal operation.

• Never wire to the wrong terminals.
• Using the Switch in a pressed-in state for an extended period of 

time can accelerate part deterioration and also lead to failure to 
return to the original position. Check the Switch beforehand, and 
perform periodic inspection and replacement.

• Do not store or use the switch with following place.

Where the temperature fluctuates greatly.
Where the humidity is very high and condensation may occur.
Where the vibration is too much.
Where receiving direct sunshine.
Where receiving salty wind.
Where exposed to cutting powder, machining chips, oil, and 
chemicals inside the protective doors.
Where exposed to cleansers, thinners, and other solvents

• Do not use or store the Switch in locations with corrosive gas, such 

as sulfuric gas (H

2

S or SO

2

), ammonium gas (NH

3

), nitric gas 

(HNO

3

), or chlorine gas (Cl

2

), or high temperature and humidity. 

Otherwise, contact failure or corrosion damage may result.

• Do not disassemble and/or modify the switch at anytime.
• Otherwise, there is the possibility of spoiling the normal operation. 

Do not apply the force such like deformation and/or degeneration 
to the switch.

• If the Switch will not be switched ON or OFF for an extended period of 

time, contact reliability may degrade due to oxidation of the contact 
points, resulting in inadequate conductivity, which could lead to an 
accident.

Operating Environment

• This switch is only for indoor use. If it is used in outdoor, it may be 

cause of switch failure.

• Take special care to use where there is fine powder, mud and/or 

foreign materials stacking. And check the condition with actual 
using condition before using. Then use without a performance 
problem.

• Seal material may deteriorate if a Switch is used outdoor or where 

subject to special cutting oils, solvents, or chemicals. Always 
appraise performance under actual application conditions and set 
suitable maintenance and replacement periods.

• Install Switches where they will not be directly subject to cutting 

chips, dust, or dirt. The Actuator and Switch must also be protected 
from the accumulation of cutting chips or sludge.

• Constantly subjecting a Switch to vibration or shock can result in 

wear, which can lead to contact interference with contacts, 
operation failure, reduced durability, and other problems. 
Excessive vibration or shock can lead to false contact operation or 
damage. Install Switches in locations not subject to shock and 
vibration and in orientations that will not produce resonance.

• The Switches have physical contacts. Using them in environments 

containing silicon gas will result in the formation of silicon oxide 
(SiO

2

) due to arc energy. If silicon oxide accumulates on the 

contacts, contact interference can occur. If silicon oil, silicon filling 
agents, silicon cables, or other silicon products are present near 
the Switch, suppress arcing with contact protective circuits (surge 
suppressor) or remove the source of silicon gas.

Installing the Switch

• To install the Switch, make a mounting panel, as shown in the 

following diagram, and tighten screws using the appropriate 
tightening torque.

* If the conduit size and ground terminal specifications are “with 

TS 1/2-14NPT ground terminal”, the back mounting hole is 4-6.2 dia. 

.

Precautions 

for Safe Use

Indicates an action that must be performed or 

avoided for safe use of this product.

Precautions 

for Correct 

Use

Indicates an action that must be performed or 

avoided for preventing operation failure or 

malfunction of the product or adverse impact 

on performance or functionality.

Precautions for Safe Use

Precautions for Correct Use

Not Suitable

Suitable

±0.15

30.2

58.7

±0.15

+0.2
  0

+0.2
  0

Front Mounting : Four, 5.2       dia. holes 
 

or M5 tapped holes

Rear Mounting : Four, 6.2       dia. holes    

+0.2
  0

Содержание WL-N

Страница 1: ...OMRON website Be sure to read Safety Precautions on pages 83 to 88 and Safety Precautions for All Limit Switches Select based on the operating temperature Ambient operating temperature of 5 C to 120...

Страница 2: ...type P1 Weather resistant type Code Specifications None Standard built in switch 55 Airtight built in switch Code Specifications None Ambient operating temperature 10 to 80 C TH Ambient operating temp...

Страница 3: ...istant type P1 Weather resistant type Code Specifications None Standard Built in Switch 55 Airtight built in switch Code Specifications None Ambient operating temperature 10 to 80 C TH Ambient operati...

Страница 4: ...2 RP60 N NC wiring WLCA2 RP60LD2 N NO wiring WLCA2 RP60LD3 N 25 5 WLCA2 2RP60 N NC wiring WLCA2 2RP60LD2 N NO wiring WLCA2 2RP60LD3 N 10 WLG2 RP60 NC wiring WLG2 RP60LD2 NO wiring WLG2 RP60LD3 5 WLGCA...

Страница 5: ...re Specifications Pretravel PT Without operation indicator Model Sealed top roller plunger Screw terminals Conduit size G1 2 Heat resistant type 1 7 mm max WLD28 TH N Cold resistant type WLD28 TC N Co...

Страница 6: ...Conduit size G1 2 Corrosion resistant type 40 20 mm WLNJ 2RP N Direct wire cable Coolant resistant type 40 20 mm WLNJ 2RP60 N Molded terminal 139 WLNJ 2139 N Molded terminal 140 WLNJ 2140 N Adjustabl...

Страница 7: ...Resistive load Lamp load Inductive load Motor load Voltage V NC NO NC NO NC NO NC NO AC 125 10 3 1 5 10 5 2 5 250 10 2 1 10 3 1 5 500 10 1 5 0 8 3 1 5 0 8 DC 8 10 6 3 10 6 14 10 6 3 10 6 30 6 4 3 6 4...

Страница 8: ...z Permissible operating speed 1 mm s to 1 m s in case of WLCA2 N Insulation resistance 100 M min at 500 VDC Contact resistance 25 m or less default value built in switch only Vibration resistance Malf...

Страница 9: ...CT cable Finished outer diameter 11 5 mm 4 conductors Resin cap 1 Fluorine rubber is used for all rubber parts 2 The connector can be removed so it is possible to use flexible conduit for the cable WL...

Страница 10: ...M5 Allen head bolt JIS B 0202 G1 2 68 7 21 6 53 2 0 8 42 max 29 2 1 2 Four M6 1 0 Depth 15 min 25 4 25 4 13 1 Roller lever R38 Heat resistant type WLCA2 TH N WLCA2 2TH N WLCA2 2NTH N Cold resistant t...

Страница 11: ...p length 5 mm 17 5 7 dia 125 4 9 15 1 40 0 7 30 2 0 2 58 7 0 2 14 7 R38 Four 5 2 dia holes 2 M3 5 Three M4 Stainless sintered roller 5 60 max 12 7 40 1 5 41 5 1 5 53 1 5 M5 Allen head bolt 68 7 21 6 5...

Страница 12: ...60 max 12 7 40 1 5 41 5 1 5 53 1 5 25 4 13 1 68 7 Four M6 1 0 Depth 15 min 25 4 21 6 53 2 0 8 42 max 29 2 1 2 Four 5 2 dia holes Three M4 SC 3M M5 Allen head bolt 17 5 7 dia 125 58 7 0 2 14 7 R38 5 4...

Страница 13: ...Four 5 2 dia holes Stainless sintered roller 5 Adjustable range 25 to 89 67 max 12 7 41 5 1 5 60 1 5 M5 Allen head bolt JIS B 0202 G1 2 68 7 65 2 0 8 42 max 21 6 29 2 1 2 Four M6 1 0 Depth 15 min 25 4...

Страница 14: ...1 2 Four M6 1 0 Depth 15 min 25 4 25 4 13 1 Vinyl cabtire cable VCT JIS C 3312 Nominal cross section 1 25 mm2 0 18 50 4 cores Strip length 5 mm Adjustable Roller Lever R25 to 89 mm Coolant resistant s...

Страница 15: ...ations WLD28 TC N Corrosion resistant specifications WLD28 RP N Note The photo shows the WLD28 TH N model Four 5 2 dia holes 17 4 6 dia PT 30 2 0 2 40 0 7 4 9 5 58 7 0 2 15 1 OP 4 M3 5 Three M4 13 1 1...

Страница 16: ...8 140 N Four 5 2 dia holes 17 4 6 dia PT 30 2 0 2 40 0 7 4 9 5 58 7 0 2 15 1 OP 4 M3 5 Three M4 13 1 12 9 21 6 29 2 1 2 42 max 68 7 28 4 Four M6 1 0 Depth 15 min Stainless sintered roller Vinyl cabtir...

Страница 17: ...5 6 5 dia 1 Do not operate the Switch in the direction of the axial center 2 Stainless steel coil spring 3 The range for operation is 1 3rd of the overall spring length from the end of the spring JIS...

Страница 18: ...pring 3 The range for operation is 1 3rd of the overall spring length from the end of the spring 20 30 2 0 2 40 0 7 15 1 4 9 Vinylcabtirecable VCTJISC3312 Nominalcross section 1 25mm2 0 18 50 4cores S...

Страница 19: ...L 3H4100 N 20 max WLCL 2N N WLRCA2 2N N WL 1H4100 N 10 WLGL WLRG2 WL 2H4100 K Sealed top plunger 1 7 mm max WLD18 N WL 7H100 N Sealed top roller plunger 1 7 mm max WLD28 N WL 7H400 N Sealed top ball p...

Страница 20: ...dia 11 dia SC 5M Cabtire cable Metal 7 dia 5 5 dia 7 5 dia SC 21 9 dia 7 5 dia 9 5 dia SC 22 12 5 dia 11 dia 13 dia SC 23 14 dia 12 dia 14 dia SC 24 11 dia 9 dia 11 dia SC 25 Cabtire cable Resin 9 di...

Страница 21: ...XS2F A421 G90 F for DC 2 2 XS2F D421 DD0 WL K13 N WL M1J N WLG K13 WLG M1J 5 XS2F D421 GD0 2 XS2F D421 DA0 F WL M1GJ N WLG M1GJ 5 XS2F D421 GA0 F 4 2 XS2F D421 D80 F WL K43 N WL M1JB N WL DGJ N WL DK1...

Страница 22: ...5 dia M12 1 45 5 dia M12 1 for DC for AC XS5F D421 80 F 40 7 L Cable length 50 30 5 M12 1 14 9 dia 1 2 3 4 Brown Blue Terminal No Cable color of core sheath 1 2 3 4 Blue Black Brown White Terminal No...

Страница 23: ...1 4 10 61 5 Brown 3 Blue 4 M4 crimp terminal 1 4 3 2 JIS B0202 G 30 dia SC 2F Built in DC connector 27 8 5 4 10 1 4 3 2 M12 1 61 5 Brown 3 Blue 4 M4 crimp terminal JIS B0202 G 30 dia SC 2FAD Built in...

Страница 24: ...1A118 Nylon Roller Roller Width 30 mm 11 4 38 16 54 8 17 9 12 6 17 5 dia length 7 stainless sintered roller 7 3 dia mounting holes Two M5 Allen head nut and arm set screw WL 1A105 Double Nuts 11 4 38...

Страница 25: ...Resin Roller 6 2 155 75 23 15 8 Adjustable lever stainless steel Adjustable range 25 to 140 19 7 0 8 24 9 0 8 17 5 dia length 7 stainless sintered roller 7 3 dia mounting holes M5 Allen head bolt WL...

Страница 26: ...bolt 13 4 8 0 4 65 2 25 5 max Adjustable from 650 to 660 7 3 dia mounting holes 3 2 dia stainless steel rod WL 3A108 7 5 7 5 11 6 13 95 M5 Allen head bolt 450 4 417 5 2 24 6 max 7 3 dia mounting holes...

Страница 27: ...O2 ammonium gas NH3 nitric gas HNO3 or chlorine gas Cl2 or high temperature and humidity Otherwise contact failure or corrosion damage may result Do not disassemble and or modify the switch at anytime...

Страница 28: ...necting the wires directly to the terminal Instead attach using a crimp terminal In the case of indicator unit to avoid interference between lump unit and crimp terminals wire according to right wirin...

Страница 29: ...nce a contact has been used to open and close a load it can no longer be used for lower loads Doing so will damage the contact surface and reduce contact reliability If an inrush current or other sudd...

Страница 30: ...ch be sure to adjust the Limit Switch carefully while considering the whole movement of the actuator The Limit Switch may soon malfunction if the OT is excessive Therefore adjustments and careful cons...

Страница 31: ...WLCL N WLCL 2 N WLCL 2N N WLGL WLCAL4 N WLCAL5 N Horizontal plunger WLSD N Top roller plunger WLD2 N Sealed top roller plunger WLD28 N Fork lock lever WLCA32 4 N Note Does not include RP60 Series or 1...

Страница 32: ...d or Lever The length of the rod or lever can be adjust ed by loosening the Allen head bolt Adjustable roller lever WLCA12 N WLCA12 2 N WLCA12 2N N WLG12 Adjustable rod lever WLCL N WLCL 2 N WLCL 2N N...

Страница 33: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Страница 34: ...60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron co...

Отзывы: