background image

Gener

al-pur

pose Switches

En

vironment-resistant Switches

Spatter-pre

vention Switches

Long-lif

e Switches

Accessor

ies

Saf

ety Precautions

33

Environment-resistant Limit Switches

WL-N/WLG

Wide range of available models to 
match your onsite environment

• Variety of head shapes, including Roller Lever, Plunger, 

and Flexible Rod Switches

• Select the optimum actuator model for the ambient operating 

temperature and operating environment for use in a wide 
range of applications

• Wiring specifications are available in Direct-wire cable types 

in addition to standard screw terminals types

Features

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

Be sure to read 

Safety Precautions

 on pages 83 to 88 and 

Safety Precautions for All Limit Switches

.

Select based on the operating temperature 

Ambient operating temperature of 5°C to 120°C: Heat-resistant type (WL

@

-TH-N/WL

@

-TH)

Ambient operating temperature of -40°C to 40°C: Cold-resistant type (WL

@

-TC-N/WL

@

-TC)

Select based on the operating environment

Outdoor use: Weather-resistant type (WL

@

-P1-N/WL

@

-P1)

Chemicals and oils: Corrosion-resistant type (WL

@

-RP-N/WL

@

-RP)

Coolant drops and mist: Coolant-resistant type (WL

@

-RP60-N/WL-RP60)

Mist 

Molded terminal 139 type (WL

@

-139-N/WL

@

-139)

 

The SC connector can be removed, so it is possible to use flexible conduit for the cable.

Constant water drops and mist Molded terminal 140 type (WL

@

-140-N/WL

@

-140)

Constant water drops or splattering cutting powder 

Molded terminal 141 type (WL

@

-141-N/WL

@

-141)

 

Molded terminal 145 type (WL

@

-145-N/WL

@

-145)

(WL

@

-RP40-N/WL-RP40)

Содержание WL-N

Страница 1: ...OMRON website Be sure to read Safety Precautions on pages 83 to 88 and Safety Precautions for All Limit Switches Select based on the operating temperature Ambient operating temperature of 5 C to 120...

Страница 2: ...type P1 Weather resistant type Code Specifications None Standard built in switch 55 Airtight built in switch Code Specifications None Ambient operating temperature 10 to 80 C TH Ambient operating temp...

Страница 3: ...istant type P1 Weather resistant type Code Specifications None Standard Built in Switch 55 Airtight built in switch Code Specifications None Ambient operating temperature 10 to 80 C TH Ambient operati...

Страница 4: ...2 RP60 N NC wiring WLCA2 RP60LD2 N NO wiring WLCA2 RP60LD3 N 25 5 WLCA2 2RP60 N NC wiring WLCA2 2RP60LD2 N NO wiring WLCA2 2RP60LD3 N 10 WLG2 RP60 NC wiring WLG2 RP60LD2 NO wiring WLG2 RP60LD3 5 WLGCA...

Страница 5: ...re Specifications Pretravel PT Without operation indicator Model Sealed top roller plunger Screw terminals Conduit size G1 2 Heat resistant type 1 7 mm max WLD28 TH N Cold resistant type WLD28 TC N Co...

Страница 6: ...Conduit size G1 2 Corrosion resistant type 40 20 mm WLNJ 2RP N Direct wire cable Coolant resistant type 40 20 mm WLNJ 2RP60 N Molded terminal 139 WLNJ 2139 N Molded terminal 140 WLNJ 2140 N Adjustabl...

Страница 7: ...Resistive load Lamp load Inductive load Motor load Voltage V NC NO NC NO NC NO NC NO AC 125 10 3 1 5 10 5 2 5 250 10 2 1 10 3 1 5 500 10 1 5 0 8 3 1 5 0 8 DC 8 10 6 3 10 6 14 10 6 3 10 6 30 6 4 3 6 4...

Страница 8: ...z Permissible operating speed 1 mm s to 1 m s in case of WLCA2 N Insulation resistance 100 M min at 500 VDC Contact resistance 25 m or less default value built in switch only Vibration resistance Malf...

Страница 9: ...CT cable Finished outer diameter 11 5 mm 4 conductors Resin cap 1 Fluorine rubber is used for all rubber parts 2 The connector can be removed so it is possible to use flexible conduit for the cable WL...

Страница 10: ...M5 Allen head bolt JIS B 0202 G1 2 68 7 21 6 53 2 0 8 42 max 29 2 1 2 Four M6 1 0 Depth 15 min 25 4 25 4 13 1 Roller lever R38 Heat resistant type WLCA2 TH N WLCA2 2TH N WLCA2 2NTH N Cold resistant t...

Страница 11: ...p length 5 mm 17 5 7 dia 125 4 9 15 1 40 0 7 30 2 0 2 58 7 0 2 14 7 R38 Four 5 2 dia holes 2 M3 5 Three M4 Stainless sintered roller 5 60 max 12 7 40 1 5 41 5 1 5 53 1 5 M5 Allen head bolt 68 7 21 6 5...

Страница 12: ...60 max 12 7 40 1 5 41 5 1 5 53 1 5 25 4 13 1 68 7 Four M6 1 0 Depth 15 min 25 4 21 6 53 2 0 8 42 max 29 2 1 2 Four 5 2 dia holes Three M4 SC 3M M5 Allen head bolt 17 5 7 dia 125 58 7 0 2 14 7 R38 5 4...

Страница 13: ...Four 5 2 dia holes Stainless sintered roller 5 Adjustable range 25 to 89 67 max 12 7 41 5 1 5 60 1 5 M5 Allen head bolt JIS B 0202 G1 2 68 7 65 2 0 8 42 max 21 6 29 2 1 2 Four M6 1 0 Depth 15 min 25 4...

Страница 14: ...1 2 Four M6 1 0 Depth 15 min 25 4 25 4 13 1 Vinyl cabtire cable VCT JIS C 3312 Nominal cross section 1 25 mm2 0 18 50 4 cores Strip length 5 mm Adjustable Roller Lever R25 to 89 mm Coolant resistant s...

Страница 15: ...ations WLD28 TC N Corrosion resistant specifications WLD28 RP N Note The photo shows the WLD28 TH N model Four 5 2 dia holes 17 4 6 dia PT 30 2 0 2 40 0 7 4 9 5 58 7 0 2 15 1 OP 4 M3 5 Three M4 13 1 1...

Страница 16: ...8 140 N Four 5 2 dia holes 17 4 6 dia PT 30 2 0 2 40 0 7 4 9 5 58 7 0 2 15 1 OP 4 M3 5 Three M4 13 1 12 9 21 6 29 2 1 2 42 max 68 7 28 4 Four M6 1 0 Depth 15 min Stainless sintered roller Vinyl cabtir...

Страница 17: ...5 6 5 dia 1 Do not operate the Switch in the direction of the axial center 2 Stainless steel coil spring 3 The range for operation is 1 3rd of the overall spring length from the end of the spring JIS...

Страница 18: ...pring 3 The range for operation is 1 3rd of the overall spring length from the end of the spring 20 30 2 0 2 40 0 7 15 1 4 9 Vinylcabtirecable VCTJISC3312 Nominalcross section 1 25mm2 0 18 50 4cores S...

Страница 19: ...L 3H4100 N 20 max WLCL 2N N WLRCA2 2N N WL 1H4100 N 10 WLGL WLRG2 WL 2H4100 K Sealed top plunger 1 7 mm max WLD18 N WL 7H100 N Sealed top roller plunger 1 7 mm max WLD28 N WL 7H400 N Sealed top ball p...

Страница 20: ...dia 11 dia SC 5M Cabtire cable Metal 7 dia 5 5 dia 7 5 dia SC 21 9 dia 7 5 dia 9 5 dia SC 22 12 5 dia 11 dia 13 dia SC 23 14 dia 12 dia 14 dia SC 24 11 dia 9 dia 11 dia SC 25 Cabtire cable Resin 9 di...

Страница 21: ...XS2F A421 G90 F for DC 2 2 XS2F D421 DD0 WL K13 N WL M1J N WLG K13 WLG M1J 5 XS2F D421 GD0 2 XS2F D421 DA0 F WL M1GJ N WLG M1GJ 5 XS2F D421 GA0 F 4 2 XS2F D421 D80 F WL K43 N WL M1JB N WL DGJ N WL DK1...

Страница 22: ...5 dia M12 1 45 5 dia M12 1 for DC for AC XS5F D421 80 F 40 7 L Cable length 50 30 5 M12 1 14 9 dia 1 2 3 4 Brown Blue Terminal No Cable color of core sheath 1 2 3 4 Blue Black Brown White Terminal No...

Страница 23: ...1 4 10 61 5 Brown 3 Blue 4 M4 crimp terminal 1 4 3 2 JIS B0202 G 30 dia SC 2F Built in DC connector 27 8 5 4 10 1 4 3 2 M12 1 61 5 Brown 3 Blue 4 M4 crimp terminal JIS B0202 G 30 dia SC 2FAD Built in...

Страница 24: ...1A118 Nylon Roller Roller Width 30 mm 11 4 38 16 54 8 17 9 12 6 17 5 dia length 7 stainless sintered roller 7 3 dia mounting holes Two M5 Allen head nut and arm set screw WL 1A105 Double Nuts 11 4 38...

Страница 25: ...Resin Roller 6 2 155 75 23 15 8 Adjustable lever stainless steel Adjustable range 25 to 140 19 7 0 8 24 9 0 8 17 5 dia length 7 stainless sintered roller 7 3 dia mounting holes M5 Allen head bolt WL...

Страница 26: ...bolt 13 4 8 0 4 65 2 25 5 max Adjustable from 650 to 660 7 3 dia mounting holes 3 2 dia stainless steel rod WL 3A108 7 5 7 5 11 6 13 95 M5 Allen head bolt 450 4 417 5 2 24 6 max 7 3 dia mounting holes...

Страница 27: ...O2 ammonium gas NH3 nitric gas HNO3 or chlorine gas Cl2 or high temperature and humidity Otherwise contact failure or corrosion damage may result Do not disassemble and or modify the switch at anytime...

Страница 28: ...necting the wires directly to the terminal Instead attach using a crimp terminal In the case of indicator unit to avoid interference between lump unit and crimp terminals wire according to right wirin...

Страница 29: ...nce a contact has been used to open and close a load it can no longer be used for lower loads Doing so will damage the contact surface and reduce contact reliability If an inrush current or other sudd...

Страница 30: ...ch be sure to adjust the Limit Switch carefully while considering the whole movement of the actuator The Limit Switch may soon malfunction if the OT is excessive Therefore adjustments and careful cons...

Страница 31: ...WLCL N WLCL 2 N WLCL 2N N WLGL WLCAL4 N WLCAL5 N Horizontal plunger WLSD N Top roller plunger WLD2 N Sealed top roller plunger WLD28 N Fork lock lever WLCA32 4 N Note Does not include RP60 Series or 1...

Страница 32: ...d or Lever The length of the rod or lever can be adjust ed by loosening the Allen head bolt Adjustable roller lever WLCA12 N WLCA12 2 N WLCA12 2N N WLG12 Adjustable rod lever WLCL N WLCL 2 N WLCL 2N N...

Страница 33: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Страница 34: ...60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron co...

Отзывы: