310
Frequency inverters
Type designation
200 V class
400 V class
Model CIMR-E7Z
@
20P4 20P7 21P5 22P2 23P7 25P5 27P5
2011
2015
2018
2022
2030
2037
2045
2055
2075
2090
2110
Max. applicable motor
output
1
1.
Standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated
current range.
2.
A 3-wire transformer is required on the power supply for 12-phase rectification.
Kw
0.55
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
O
u
tput
ch
ar
a
c
te
ri
st
ic
s
Inverter capacity kVA
1.2
1.6
2.7
3.7
5.7
8.8
12
17
22
27
32
44
55
69
82
110
130
160
Rated current
A
3.2
4.1
7.0
9.6
15
23
31
45
58
71
85
115
145
180
215
283
346
415
Max. voltage
3-phase; 200, 220, 230, or 240 VAC (proportional to input voltage)
Max. output frequency
200.0
Powe
r
suppl
y
Rated input voltage and
frequency
3-phase, 200/208/220/230/240 VAC, 50/60 Hz
Allowable voltage
fluctuation
+ 10%, - 15%
Allowable frequency
fluctuation
±5%
Harmonic
wave
prevention
DC reactor
Optional
Built in
12-pulse input
Not possible
Possible*2
Model CIMR-E7ZZ
@
40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
IP54 model: CIMR-E7Z
---
---
---
---
---
---
---
47P52 40112 40152 40182 40222 40302 40372 40452 40552 ---
---
---
---
---
---
---
---
Max. applicable motor
output
1
1.
Standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated
current range.
2.
A 3-wire transformer is required on the power supply for 12-phase rectification
*
To agg 400 V class
Kw
0.55 0.75 1.5
2.2
3.7
4.0
5.5
7.5
11
15 18.5 22
30
37
45
55
75
90
110 132 160 185 220 300
O
u
tput
cha
rac
ter
is
ti
c
s
Inverter capacity kVA 1.4
1.6
2.8
4.0
5.8
6.6
9.5
13
18
24
30
34
46
57
69
85
110 140 160 200 230 280 390 510
Rated current
A
1.8
2.1
3.7
5.3
7.6
8.7 12.5
17
24
31
39
45
60
75
91
112 150 180 216 260 304 370 506 675
Max. voltage
3-phase; 380, 400, 415, 440, 460, or 480 VAC (proportional to input voltage)
Max. output frequency
200.0
Powe
r
suppl
y
Rated input voltage and
frequency
3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz
Allowable voltage
fluctuation
+ 10%, - 15%
Allowable frequency
fluctuation
±5%
Harmonic
wave
prevention
DC reactor
Optional
Built in
12-pulse input
Not possible
Possible
*2
C I M R – E 7 Z 4 0 P 4 0
Inverter
Protective enclosure
0: Open chassis type (IP00)
1: Enclosed type (IP20 / NEMA 1)
2: Enclosed type (IP54)
Max. applicable motor output
0P4: 0.4 kW
022: 22 kW
300: 300 kW
E7 series
Specifications
Z: European standard
specifications
Voltage
2: 200 V class
4: 400 V class
"P" indicates a decimal
point
[ ]
~
~
Y203-EN2-02-Katalog.book Seite 310 Mittwoch, 24. Mai 2006 2:22 14