Settings Page
Use the Modify
Settings
page to change RFID
protocol, network and reader security settings. The
page is divided into five sections: RFID Protocol
Settings; Network Settings: All Interfaces; Network
Settings: Ethernet Interface; Boot Options and
Security Settings.Instructions for Modifying the
Settings.
1. Click
the
Settings
link on the navigation menu.
The
Modify
Settings
page appears.
2. Enter the required settings.
3. Click
the
Save Changes
button to save the new
settings.
IMPORTANT:
Do not disconnect power until the
save process is complete.
(see 1.5.2 Restarting the Reader on page 25).
Instructions for Modifying the Settings
Changing these parameters changes the reader’s
settings used on startup. RFID protocol settings, boot
options and network settings can be modified. Care
must be taken to use correct values or you might be
unable to connect the reader without restarting into
safe mode.
IMPORTANT
: Do not disconnect power until the save
process is complete.
Static network settings are ignored when in DHCP
mode, and DHCP related settings are ignored when in
static IP mode. Please note that your network needs
to have properly configured DNS servers if you wish
to connect to the reader via its hostname. Usually
when using DHCP, the DHCP server will add the
hostname to the DNS server’s database.
The reader adjusts time by NTP only once when it
starts up. You should confirm if the time is correct
using
Get information
command (Ref. Section
2.2.4.4).
Note that new RFID, network and security settings
take effect after saving. Boot-related options are
saved but DO NOT take effect until the reader is
restarted. Therefore, to ensure that all new settings
take effect, it is recommended that you restart the
reader whenever reconfiguring and after saving the
new settings.
Note:
Please ask the network administrator about the