(20/23)
(7) NACK
When the User board was not able to receive a response correctly, NACK is
transmitted to demand that the response to be transmitted again. When the R/w
Module receives this command, the most recent response will be transmitted
again.
n
Command
Command
Terminator
“1”
“2”
Cr
n
Response
The most recent response will be transmitted again.
(8) STOP
The STOP command is used to stop the R/W Module from executing a
command. When the R/W Module receives this command, it immediately stops
the execution of the current command and sets on stand by mode for a new
command.
n
Command
Command
Terminator
“1”
“3”
Cr
n
Response
Completion Code
Terminator
“0”
“0”
Cr
(9) Oscillation ON / OFF
The Oscillation ON / OFF command specifies the oscillation of the antenna.
n
Command
Oscillation ON
Oscillation OFF
Command
Terminator
Command
Terminator
“1”
“4”
Cr
“1”
“5”
Cr
n
Response
Completion Code
Terminator
“0”
“0”
Cr