manualshive.com logo in svg
background image

RFID SYSTEM

V640 SERIES

CIDRW SYSTEM
V640 Utility Tool

OPERATION MANUAL

V640-HAM11-ETN-V2
V640-HAM11-L-ETN-V2

Z469-E1-01

Содержание V640

Страница 1: ...RFID SYSTEM V640 SERIES CIDRW SYSTEM V640 Utility Tool OPERATION MANUAL V640 HAM11 ETN V2 V640 HAM11 L ETN V2 Z469 E1 01 ...

Страница 2: ... subject to change without notice Every precaution has been taken in the preparation of this manual Nevertheless OMRON assumes no responsibility for errors or omis sions Neither is any liability assumed for damages resulting from the use of the information contained in this publication Trademarks Microsoft Windows NET Framework are either registered trademarks or trademarks of Microsoft Corporatio...

Страница 3: ...ing operation Intended Audience This manual is intended for the following personnel who must also have knowledge of electrical sys tems an electrical engineer or the equivalent Personnel in charge of introducing CIDRW systems Personnel in charge of designing CIDRW systems Personnel in charge of installing and maintaining CIDRW systems Personnel in charge of managing CIDRW systems and facilities Ap...

Страница 4: ...il they click into place Precautions for Correct Use Precautions for Correct Use 4 3 1 Connecting Controller Components Connector Hook Hook holes Slider Lock Release Move the sliders toward the back until they lock into place Level 1 heading Level 2 heading Level 3 heading Level 2 heading A step in a procedure Manual name Special information Level 3 heading Page tab Gives the current headings Indi...

Страница 5: ... what to do and what to avoid doing to ensure proper operation and perform ance Additional Information Additional information to read as required This information is provided to increase understanding or make operation easier Version Information Information on differences in specifications and functionality between versions is given Manual Structure 3 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640...

Страница 6: ...Manual Structure 4 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 7: ...n this Manual Sections in this Manual 5 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 1 2 3 1 2 3 Overview and Specifications Basic Operation of V640 Utility Tool V640 Utility Tool Features ...

Страница 8: ...WARNING 14 Precautions for Safe Use 16 Precautions for Correct Use 17 Related Manuals 18 Revision History 19 Section 1 Overview and Specifications 1 1 Overview of Configuration Tool 1 2 1 2 System Environment 1 3 1 3 Installation and Uninstallation 1 4 1 3 1 Installation 1 4 1 3 2 Uninstallation 1 4 Section 2 Basic Operation of V640 Utility Tool 2 1 Set the IP address of the computer 2 2 2 1 1 Def...

Страница 9: ...ndow Configuration 3 2 3 2 Status Window 3 3 3 3 Setting Window 3 5 3 4 Command Window 3 6 3 4 1 CID R W 3 6 3 4 2 V640 Command 3 8 3 5 Noise Measurement Window 3 11 CONTENTS 7 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 10: ...ying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be re sponsible for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled stored installed and maintained and not subject to contamination abuse misuse o...

Страница 11: ...R AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT S IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIP MENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Prod...

Страница 12: ...INDIRECTLY RESULTING FROM THE INFECTION OF OMRON PROD UCTS ANY SOFTWARE INSTALLED THEREON OR ANY COMPUTER EQUIPMENT COMPUTER PROGRAMS NETWORKS DATABASES OR OTHER PROPRIETARY MATERIAL CONNECTED THERETO BY DISTRIBUTED DENIAL OF SERVICE ATTACK COMPUTER VIRUSES OTHER TECHNOLOGICALLY HARMFUL MATERIAL AND OR UNAUTHORIZED ACCESS It shall be the users sole responsibility to determine and use adequate meas...

Страница 13: ...es in the obvious way 4 DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS The User must not remove or alter any copyright notices on all copies of this Software 5 The User shall not modify any portion of this Software If the User modifies this Software OMRON assumes no responsibility for the results of any modifications made by the User including defects or damages of any nature 6 The User may not distr...

Страница 14: ...elevant countries with regard to security export control when exporting this Software and or technical documents or providing such products and or documents to a non resident Omron may not pro vide the User with this Software and or technical documents should they fail to comply with such laws and regulations 19 MISCELLANEOUS This agreement constitutes the entire agreement between the parties conc...

Страница 15: ...ly foreseeable loss or damage Licensee is also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure b To the full extent permitted by Law where the benefit of any such condition warranty or other obligation is conferred upon Licensee pursuant to the ACL Omron s sole liability for breach of any such conditio...

Страница 16: ...s shown in the circle and explained in text This example indicates prohibiting disassembly The triangle symbol indicates precautions including warnings The specific operation is shown in the triangle and explained in text This example indicates a precaution for electric shock The triangle symbol indicates precautions including warnings The specific operation is shown in the triangle and explained ...

Страница 17: ...security Manage usernames and passwords for this software carefully to protect them from un authorized uses Set up a firewall E g disabling unused communication ports limiting communication hosts etc on a network for a control system and devices to separate them from other IT networks Make sure to connect to the control system inside the firewall Use a virtual private network VPN for remote access...

Страница 18: ...ls on Precautions for Safe Use please refer to Precautions for Safe Use in V640 HAM11 L ETN V2 HS61 HS62 CIDRW SYSTEM USER S MANUAL Z361 E1 Precautions for Safe Use 16 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 19: ...ions on the correct use of the product please refer to Precautions for Correct Use in V640 HAM11 L ETN V2 HS61 HS62 CIDRW SYSTEM USER S MANUAL Z361 E1 Precautions for Correct Use 17 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 20: ...ons installation and connection wiring prepara tion for communication reading writing to from ID tags and browser interface are de scribed V640 series CIDRW System Utility Tool OPERATION MAN UAL Z469 E1 When you want to know how to operate the amplifier unit of the V640 series CIDRW System with the V640 Utility Tool V640 Utility Tool for operating the amplifier units of the V640 series CIDRW sys t...

Страница 21: ...fix to the catalog number on the front and back covers of the manual Z469 E1 01 Revision code Cat No Revision code Date Revised content 01 October 2022 First Publication Revision History 19 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 22: ...Revision History 20 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 23: ...ool system environment and instal lation uninstallation 1 1 Overview of Configuration Tool 1 2 1 2 System Environment 1 3 1 3 Installation and Uninstallation 1 4 1 3 1 Installation 1 4 1 3 2 Uninstallation 1 4 1 1 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 1 ...

Страница 24: ...If your PC environment is Windows 10 or Windows 11 we recommend that you use this tool The V640 series amplifier units that can use the V640 Utility Tool are as follows Product name Model Version CIDRW Amplifier Unit V640 HAM11 ETN V2 Ver1 00 1 01 V640 HAM11 L ETN V2 Ver1 00 1 01 1 Overview and Specifications 1 2 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 25: ...ty Tool Item Requirement Operating system OS Windows 10 32 bit or 64 bit edition Windows 11 Operating condition NET Framework 4 6 or higher is installed 1 Overview and Specifications 1 3 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 1 2 System Environment 1 ...

Страница 26: ...stallation necessary Start by double clicking V640 Utility Tool exe 1 3 2 Uninstallation No software uninstallation necessary Delete V640 Utility Tool exe as appropriate 1 Overview and Specifications 1 4 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 27: ...w to start and shutdown 2 1 Set the IP address of the computer 2 2 2 1 1 Default IP Address Settings of the Amplifier Unit 2 2 2 1 2 Setting the IP Address of the Computer with Windows 10 2 2 2 2 Getting Started 2 3 2 3 Shutting Down 2 5 2 1 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 2 ...

Страница 28: ...dress of the Computer with Windows 10 1 Open the Control Panel and select Network and Internet and then Network and Sharing Center 2 Select Change adapter settings and then right click Local Area Connection 3 Right click Local Area Connection and select Properties 4 Select Internet Protocol Version 4 TCP IPv4 and then click the Properties Button Change the last part of the IP address to a value ot...

Страница 29: ...n 3 If you have set a password for the V640 the password window will appear after you press the Connect button Enter the correct password and press the OK button The following characters can be used for the password 0 to 9 a to z and A to Z 4 If the connection is successful the status window will be displayed 2 Basic Operation of V640 Utility Tool 2 3 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640...

Страница 30: ...2 Basic Operation of V640 Utility Tool 2 4 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 31: ... To shut down V640 Utility Tool click the X mark in the top right corner of the Top page 2 Basic Operation of V640 Utility Tool 2 5 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 2 3 Shutting Down 2 ...

Страница 32: ...2 Basic Operation of V640 Utility Tool 2 6 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 33: ...en configuration and each function 3 1 Window Configuration 3 2 3 2 Status Window 3 3 3 3 Setting Window 3 5 3 4 Command Window 3 6 3 4 1 CID R W 3 6 3 4 2 V640 Command 3 8 3 5 Noise Measurement Window 3 11 3 1 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 3 ...

Страница 34: ...ration The window structure of the V640 Utility Tool is shown as follows Language Switch List Menu Buttons Main Display 3 V640 Utility Tool Features 3 2 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 35: ...played DIP SW Enabled is displayed if the Amplifier Unit is set to use the IP address that is set on the DIP switch Disabled is displayed if the Amplifier Unit is set to use the IP address that is set in ROM 2 Network Setting Information Item Description Comments Network Settings DIP If the Amplifier Unit is set to use the IP address that is set on the DIP switch this item is displayed in blue and...

Страница 36: ...pli fier Unit was started Command Code Response Code 4 Communications History Information Item Description Comments Communication History History information on communications with the ID Tags is displayed Total Total number of communications Success Total number of successful communications Error Total number of failed communications 5 Hardware Information Item Description Comments H W Status Har...

Страница 37: ... Description Comments New Password You can set a new password If the Save Button is clicked when the password box is empty the password will be cleared In this state theV640 Utility Tool V640 Utility Tool and browser interface can be used without entering the password The following characters can be used for the pass word 0 to 9 a to z and A to Z Precautions for Correct Use Never turn OFF the powe...

Страница 38: ...d V640 Command CID R W V640 Command 3 4 1 CID R W The CID R W Window allows you to read or write ID Tag data by specifying the offset length and maximum bytes of CID If writing is executed you must also specify the write data 3 V640 Utility Tool Features 3 6 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 39: ...Repeat Check this box if the program is to be run repeatedly Command Commands actually sent to the amplifier unit are displayed Communications Results Display Area Transmitted and received data to the amplifier unit are displayed TX The data transmitted toward the amplifier unit is displayed RX The data received from the amplifier unit is displayed Execution example For example the results display...

Страница 40: ...not visible ASCII characters are detected for a CID read they will be converted to asterisks Characters that are not visible ASCII characters are converted to 3 4 2 V640 Command The V640 Command Window allows you to read and write data according to the command format of the Amplifier Unit 3 V640 Utility Tool Features 3 8 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 41: ... Tag as a hexa decimal string Specify 16 characters for each page that you specify in the Page Designation Area Repeat Check this box if the program is to be run repeatedly Send Button Press the Send button to send the command When you press the Send button on the right side of the Command the content displayed in the Command is sent Command Commands actually sent to the amplifier unit are display...

Страница 42: ...Failed Communications 3 V640 Utility Tool Features 3 10 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 43: ...e Amplifier Unit and display the results in real time The horizontal axis gives the time and the vertical axis gives the noise level 0 to 99 Peak noise level Start Stop Button Graph Clear Button 3 V640 Utility Tool Features 3 11 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 3 5 Noise Measurement Window 3 ...

Страница 44: ...3 V640 Utility Tool Features 3 12 V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool Z469 E1 ...

Страница 45: ......

Страница 46: ... Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 OMRON Corporation Industrial Automation Company Cat No Z469 E1 01 1022 OMRON Corporation 2022 All Rights ...

Отзывы: