45
V530-R160
Operation Manual
SE
C
T
IO
N
2
Power Supp
ly
a
nd Gr
ound
SECTION 2
Installation and Connections
Wiring the Power Supply
Wire the Power Supply Unit independently of other devices. In particular, keep the power supply
wired separately from inductive loads.
Use a power supply with the following specifications.
Use a DC power supply with safe extra low-voltage circuits on the secondary side.
If UL recognition is required, use a UL class II power supply.
Cover the power supply with the Terminal Block Protection Cover. Uncovered terminal blocks can
cause electric shock.
Condition
Recommended model
Output current
Power supply
voltage
Manufacturer
Model
1.6 A min.
20.4 to 26.4 VDC
OMRON
S8VS-06024
Keep the power supply cable as short as possible (10 m max.).
24VDC
+
-
V530-R160
24 VDC
+
-
Terminal Block Protection Cover
(Transparent)
24VDC
+
-