manualshive.com logo in svg
background image

D-54

Inductive Sensors

Rating/Performance

DC 2-wire Models

* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the

size of the sensing object and the sensing distance set is half of the maximum sensing distance.

Item

Model

TL-W5MD

#

Sensing distance

5 mm ±10%

Setting distance

0 to 4 mm

Differential distance

10% max.

Sensing object

Ferrous metal(Sensitivity decreases with non-ferrous metals)

Standard sensing object

Iron, 18 x 18 x 1 mm

Response frequency

0.5 kHz

Rated supply voltage 
(operating voltage)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Leakage current

0.8 mA max.

Control 
output

Switching capacity

3 to 100 mA

Residual voltage

3.3 V max. (under load current of 100 mA with cable length of 2 m)

Indicator lamp

D1 models: Operation indicator (Red LED), Operation set indicator (Green LED) 
D2 models: Operation indicator (Red LED)

Operating status 
(with sensing object approaching)

D1 models: NO 
D2 models: NC

Protective circuits

Surge absorber, short-circuit protection

Ambient temperature

Operating/Storage: -25°C to 70°C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95%RH (with no condensation)

Temperature influence

±10% max. of sensing distance at 23°C within a temperature range of -25°C and 70°C

Voltage influence

±2.5% max. of Sensing distance within a rated voltage range ±15%.

Insulation resistance

50 M  min. (at 500 VDC) between energized parts and case

Dielectric strength

1,000 VAC for 1 min between energized parts and case

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s

2

 for 3 times each in X, Y, and Z directions

Protective structure

IEC60529 IP67

Connection method

Pre-wired models (standard length: 2 m)

Weight (Packed state)

Approx. 45 g

Material

Case

Heat-resistant ABS resin

Sensing 
surface

Accessories

Instruction manual

F502-EN2-04.book  Seite 54  Dienstag, 26. Juli 2005  5:48 17

Содержание TL-W

Страница 1: ...ilable These model numbers take the form TL W5MD 5 e g TL W5MD15 TL W5MD2 1 5mm Shape Sensing distance Output specifications Model Output and operating status PNP NO PNP NC NPN NO NPN NC DC 3 wire TL W1R5MB1 TL W1R5MC1 1 1 Models with different response frequency are available These model numbers take the form TL W5MD 5 e g TL W5MD15 TL W3MB1 TL W3MB2 TL W3MC1 1 TL W3MC2 TL W5MB1 TL W5MB2 TL W5MC1...

Страница 2: ...on set indicator Green LED D2 models Operation indicator Red LED Operating status with sensing object approaching D1 models NO D2 models NC Protective circuits Surge absorber short circuit protection Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influence 10 max of sensing distance at...

Страница 3: ...tor lamp Detection indicator red LED Operating status with sensing object approaching NO C1 models NO C2 type NC E1 models F1 models NO E2 models F2 models NC Protective circuits Reverse connection protection surge absorber Ambient temperature Operating Storage 25 C to 70 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 RH with no condensation Temperature influ ence 10 m...

Страница 4: ...of sensing object d mm Brass Aluminum Iron Copper Stainless steel SUS304 7 6 5 4 3 2 1 0 10 20 30 40 50 60 Brass Aluminum Iron Copper Stainless steel SUS304 Sensing distance X mm Side length of sensing object d mm d t 1mm X 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 Sensing distance X mm Side length of sensing object d mm Brass Aluminum Iron Stainless steel SUS304 d t 1mm X 24 22 20 18 16 14 12 10 8 ...

Страница 5: ...ator red Rated sensing distance 100 Control output Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Maximum load current 100 mA Output Load Brown Black Blue 100W Main circuit V 0V Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Sensing object Yes No Output transistor load ON OFF Operation indicator red ON OFF Load Brown Black Blu...

Страница 6: ...er ate an error pulse for approximately 1 ms NO TL W5F1 NC TL W5F2 Operating status Model Timing chart Output circuit Sensing object Yes No Operate Release Load between brown and black Output voltage between blue and black H L Operation indicator red ON OFF Brown V Tr Black 2 1 2 2W 4 7kW Blue 0V Output Main circuit 100W Load 1 Maximum load current 200 mA 2 Current flows in this direction if the c...

Страница 7: ...ttachment TL W5M 30 5 12 5 18 8 5 4 5 4 18 10 8 7 5 6 5 5 3 5 1 TL W5MC1 Vinyl insulated round cable with three conductors 4 dia conductor cross sectional area 0 2 mm2 insulation diameter 1 2 mm standard length 2 m TL W5MD Vinyl insulated round cable with two conductors 4 dia conductor cross sectional area 0 3 mm insulation diameter 1 3 mm standard length 2 m 2 C type Operation indicator red D typ...

Страница 8: ... of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No E221 E2 03 X ...