Model after
change
CS1W
-EIP21
CJ1W
-EIP21
CJ1W
-EIP21
(CJ2)
CJ2B-
EIP21
CJ1W
-EIP21
(NJ)
CJ2M
NJ501-
££££
NJ301-
££££
NJ101
NX701
NX102
NX1P2
Model
before
change
CIP
Rev
Rev2
Rev3
Rev3
Rev3
Rev3
Rev3
Rev1
Rev2
Rev2
Rev 2
Rev2
CJ1W-
EIP21
Rev3
Yes
---
Yes
Yes
r
5
r
3
r
4/5
r
4/5
No
No
No
CJ1W-
EIP21
(CJ2)
Rev3
r
1
r
1
---
Yes
r
5
r
3
r
4/5
r
4/5
r
5
r
4/5
r
4/5
CJ2B-
EIP21
Rev3
r
1
r
1
Yes
---
r
5
r
3
r
4/5
r
4/5
r
5
r
4/5
r
4/5
CJ1W-
EIP21
(NJ)
Rev3
r
1/2
r
1/2
r
2
r
2
---
r
2/6
r
4
r
4
Yes
r
4
r
4
CJ2M
Rev3
r
1
r
1
Yes
Yes
r
5
---
r
4/5
r
4/5
r
5
r
4/5
r
4/5
NJ501-
£
£££
NJ301-
£
£££
NJ101
Rev1
r
1/2
r
1/2
r
2
r
2
Yes
r
2/6
---
Yes
No
No
No
Rev2
r
1/2
r
1/2
r
2
r
2
Yes
r
2/6
Yes
---
Yes
r
4
r
4
NX701
Rev2
No
No
r
2
r
2
Yes
r
2/6
No
r
4
---
r
4
r
4
NX102
Rev 2
No
No
r
2
r
2
Yes
r
2/6
No
Yes
Yes
---
r
4
NX1P2
Rev2
No
No
r
2
r
2
Yes
r
2/6
No
Yes
Yes
Yes
---
*1.
CPU Unit with a unit version 1.00 to 1.02
*2.
CPU Unit with a unit version 1.03 or later
Yes
Can be changed.
No:
Cannot be changed.
r
1
Cannot be changed if a network variable is specified as a tag.
r
2
Cannot be changed if the maximum size of a tag name or tag set name (size after conversion into
UTF-8) exceeds 48 bytes.
r
3
Cannot be changed if the following items exceed the permissible settings of the device after the
change:
•
Number of I/O connections, number of tags, number of tag sets, and size of one tag set.
r
4
Cannot be changed in any of the following cases:
•
The number of I/O connections, number of tags, number of tag sets, or size of one tag set ex-
ceeds the permissible settings for the device after the change.
•
RPI exceeds the permissible settings or is set in 0.5-ms increments (such as 10.5ms)
r
5
Cannot be changed if a tag set size is an odd number of bytes.
r
6
Cannot be changed if tags, tag sets, or refreshing sizes exceed the permissible settings.
7-2-18
Displaying Device Status
Device status is displayed using the following icons in Maintenance Mode.
To enter Maintenance Mode, select
Large Icons - Maintenance Mode
from the
View
Menu.
7 Tag Data Link Functions
7-78
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......