7
High-speed Counter
CPM1 PCs have a high-speed counter that can be used in incremental mode or
up/down mode. The high-speed counter can be combined with input interrupts
to perform target value control or zone comparison control that isn’t affected by
the PC’s cycle time.
Count input
Reset input
Solenoid
Sensor
Rotary Encoder
Motor
Controller
00000
00001
00002
Motor
controller
Mode
Input functions
Input method
Count
frequency
Count
range
Control methods
Up/Down
00000: A-phase input
00001: B-phase input
00002: Z-phase input
Phase-difference,
4
×
inputs
2.5 kHz
–32767
to
32767
Target value control:
Up to 16 target values and interrupt
subroutine numbers can be
registered.
Incremental
00000: Count input
00001: See note.
00002: Reset input
Individual inputs
5.0 kHz
0
to
65535
Zone comparison control:
Up to 8 sets of upper limit values,
lower limit values, and interrupt
subroutine numbers can be
registered.
Note In incremental mode, this input (00001) can be used as an regular input.
Refer to the CQM1/CPM1/CPM1A/SRM1 Programming Manual (W228) for set-
ting and using the high-speed counter.
CPM1 Features and Functions
Section 1-1
Содержание SYSMAC CPM1
Страница 1: ...Cat No W262 E1 4 Programmable Controllers SYSMAC CPM1 OPERATION MANUAL ...
Страница 2: ...CPM1 Programmable Controllers Operation Manual Revised February 1998 ...
Страница 116: ...105 Appendix B Dimensions All dimensions are in millimeters CPM1 10CDR j 121 130 85 81 90 ...
Страница 117: ...Appendix B Dimensions 106 CPM1 20CDR j 85 171 180 81 90 CPM1 30CDR j CPM1 30CDR j V1 Available soon 85 221 230 81 90 ...
Страница 118: ...Appendix B Dimensions 107 CPM1 20EDR 81 90 171 180 85 ...
Страница 119: ...Appendix B Dimensions 108 CPM1 CIF01 90 81 21 30 205 50 56 CPM1 CIF11 90 81 21 30 205 50 61 ...