713
V600/V620 ID Controller Protocol
Appendix P
Write (ASCII/8) (Sequence No. 521 (Hex 0209))
This sequence is used when the number of Heads to be written to the Carrier is 8. Up to 20 bytes of data can
be read for each Read/Write Head.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note
Write data designated for ASCII is sent beginning with the smallest offset from the send data words.
Offset
Contents (data format)
Data
+0
Number of send data
words(4 digits Hex)
0007 to 0072 (7 to 114 decimal)
+1
Number of Heads
(4 digits BCD)
0001 to 0008
+(14(N–1)+2)
Unit No. (2 digits BCD)
Arbitrary (However, there is a limit for the max-
imum Unit No. depending on the model)
+(14(N–1)+3)
R/W Head CH No.
(1 digit BCD)
R/W Head CH 1 designation: 1
R/W Head CH 2 designation: 2
The CD1D must be set to 1.
+(14(N–1)+4)
Leading address No.
(4 digits Hex)
0000 to FFFF
+(14(N–1)+5)
Number of write bytes
(4 digits Hex)
0001 to 0014 (1 to 20 decimal)
+(14(N–1)+6) to
(14(N–1)+15)
Write data (ASCII)
Input in ASCII
Up to 20 bytes (max.) can be set
N: Number of Heads
First word of send
data
Number of Heads
+0
+1
+2
+3
+4
+5
+6
+15
+16
+17
+18
+19
+20
+29
+100
+101
+102
+103
+104
+113
CH 1
Number of send data words
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
CH 2
Number of write bytes
Write data
~
~
Write data
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
Number of write bytes
Write data
~
~
Write data
~
~
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
Number of write bytes
Write data
~
~
Write data
CH 8
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...