631
V500/V520 Bar Code Reader Protocol
Appendix M
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
General-purpose Command 2 (Sequence No. 366 (Hex 016E))
This general-purpose command is used to send data with a specified data length, and receive back ACK in
addition to other receive data. The frame format of the receive data, however, has to contain STX and ETX.
STX and ETX are automatically attached to the send data.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Storage Word Allocation (4th Operand of PMCR(260))
Note
Shown below is the receive data frame format. The reception data without ACK, STX, and ETX is stored.
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 to 00FA (3 to 250 decimal)
+1
Send data byte length
(4 digits Hex)
0001 to 01F0 (1 to 496 decimal)
The byte length of the send data excluding STX and
ETX.
+2 to
+249
Send data (ASCII)
Inscribe send data up to 496 bytes (max.) by ASCII.
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 to 00FA (3 to 250 decimal)
+1
Send data byte length
(4 digits Hex)
0001 to 01F0 (1 to 496 decimal)
The byte length of the send data excluding STX and
ETX.
+2 to
+128
Send data (ASCII)
Set send data up to 496 bytes (max.) by ASCII.
Offset
Contents (data format)
Data
+0
Number of receive data
words (4 digits Hex)
0001 to 00FA (1 to 250 decimal)
+1 to
+127
Receive data (ASCII)
Up to 498 bytes of ASCII receive data are stored.
Send data
Send data
+0
+1
+2
+3
+248
+249
Number of send data words
First word of
send data
~
~
Send data
Send data
Send data byte length
Receive data
Receive data
+0
+1
+2
+126
+127
Number of receive data words
Receive data
storage words
~
~
Receive data
Receive data
Receive data (498 bytes max.)
ACK
STX
ETX
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...